PANEL REVIEW
Press FUN button:
Switch to function menu or return to previous menu
Press UP/DOWN:
Adjusts the currently activated field. The four points will blink indicating
a value change.
Press ENTER
: Enter into sub-menu or confirm the current value.
INSTALLATION AND SETTING
1. MULTI-FIXTURES CONNECTION
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain
connection is where the DATA OUT of one fixture connects to the DATA IN of the next
fixture. The order in which the fixtures are connected is not important and has no effect on
how a controller communicates to each fixture. Use an order that provides for the easiest
and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable
with three pin XLR male to female connectors.
The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive
(S+).