background image

TSLM - M601 Operational & Install Manual          

SetView Software 

Introduction

The SetView software connects to 

older TSLM

 units to allow you to:

Update firmware

View and record parameters

View and adjust configuration / settings

Retrieve and view history logs

Share history, configuration and recordings via email

Do diagnostic tests for troubleshooting

The 

new TSLM

 (serial numbers 7XXX) connect via VRX multi-function display in order to perform 

the above tasks. For details see the VRX-M601 Operational and Install Manual.

System Requirements

Operating System: Windows 7 or higher

One available serial port. If no serial port is available, a USB port together with a USB-to-
Serial Converter can be used.

SetView download and Installation

Find the latest version of SetView on our website (

www.vravionics.com

) and install it onto your 

Windows computer or laptop:

Click on the 

SetView Software

 link found at (

www.vravionics.com/downloads.html

)

Click on 

Install

 and run the setup.exe until all is successfully installed.

Bundled with the latest software are the latest firmware for all VR units in your system (EIU, TSLM, 
PDC, FSM, etc.). This new firmware may provide new features or have corrected old problems.

Using SetView

Through its dedicated 9 pin maintenance connector the TSLM can link with your computer / laptop 
connecting either directly to your computer’s serial port or via a USB-to-Serial converter.

Plug in your USB-to-Serial converter (if you are using one) to your Laptop. If this is the first 
time it have been plugged into a specific USB port, wait for Windows to recognize it and  
successfully install its driver.

Connect the USB-to-Serial converter serial port to the 9 pin maintenance connector.

Run the SetView Software.

Select from the main menu System > Serial Port. Confirm you have a COM port selected  
and that it is the right one.

Power the TSLM module (by switching on the aircraft’s master switch).

Reasons for failing to establish communication could be: 

Power was not applied to the TSLM, or

The serial cable between the unit and the laptop is not connected properly, or

The correct serial port was not selected, or

The USB-to-Serial converter driver was not properly installed. If you have bought a new 
USB-to-Serial converter, you first need to get it to work with Windows on your computer. 
Plug only the USB-to-Serial converter into the laptop / PC, let Windows recognize it and  
install the relevant driver first. Only when this is complete and Windows tells you that the 
device is ready to be used, should you plug it into the TSLM, start the SetView software 
and switch the power on.

06/29/16   

© 2016 VR Avionics

page 30 of 33

Содержание Walter M601

Страница 1: ...TSLM for Walter M601 Engines OPERATIONAL INSTALL MANUAL Updated 29 June 2016 Copyright 2016 by VR Avionics...

Страница 2: ...personal use provided that such electronic or printed copy of this manual or revision must contain the complete text of this copyright notice and provided further that any unauthorized commercial dis...

Страница 3: ...ols and Equipment 13 Electrical Installation 14 Power and Ground 15 Ignition Circuit 16 Start Run Selection 17 Start Contactor 17 Start Interrupter Valve 18 Limiting EHT Circuit 19 TSLM Status Light 2...

Страница 4: ...ype 28 Force a Start sequence when double clicking Start Button 28 Walter Engine Type 0 M601D 1 M601E 11 2 M601E 11A 28 Start ITT Control Setting 28 History Logs Operations 28 History retrieval 28 His...

Страница 5: ...remote mount it will have little to no impact on your current instrument panel if start control and limiting is all you require You can however choose to add a VRX multi function display shown here fo...

Страница 6: ...no code Initiating a Start By depressing the START button you initiate a start sequence The TSLM performs pre start checks first unless commanded to bypass them see later It checks that the ITT is co...

Страница 7: ...nnected in some way that would only become apparent after light off the TSLM will sense this and immediately turn on the EXCEED light Since the TSLM can no longer measure the ITT accurately in this co...

Страница 8: ...g the BETA micro switch Anti Flameout Operation AFO In anti flameout operation the igniters and ignition fuel valves are continuously activated as a precautionary measure against engine flameout This...

Страница 9: ...on repair With the graph you will not only identify the parameter exceeded but obtain both the maximum it reached as well as the time it spent above the maximum limit With this you will be able to loo...

Страница 10: ...and ITT have stabilized switch the generator ON 15 Check Oil and Fuel Pressure 16 Forward Prop to full fine pitch RUN 1 Master switch On 2 Throttle to idle 3 Propeller to Feather 4 Condition lever in...

Страница 11: ...0 to 32 VDC Supply Current start or run sequence 10 A Supply Current monitoring only 50 mA Operating Temperature 40 C to 85 C Storage Temperature 55 C to 125 C Dimensions SN 7001 and later Weight 180g...

Страница 12: ...es a RS232 interface 9600 baud 8 data bits 1 stop bit no parity to link to a Personal Computer Laptop or similar device The pins used on the DB 9 port are as follows 2 RXD 3 TXD 5 GND The TSLM will tr...

Страница 13: ...rsonal computer running Windows 98 or higher with a spare serial port If no serial port a USB port together with a USB to Serial adapter will do Standard RS 232 cable DB 9 male to DB 9 female Torque a...

Страница 14: ...pment VR Avionics does not supply connectors or wire for wiring up your TSLM We recommend that standard aircraft grade wiring and connectors be used during installation 20 gauge wire is sufficient for...

Страница 15: ...nerator Speed Sensing N1 Propeller Speed Sensing N2 Inter Turbine Temperature Sensing ITT Power and Ground The maximum current drawn by the TSLM unit is 10 Amps thus we have to ensure the circuit brea...

Страница 16: ...independent ignition checking through a toggle switch The next figure shows the wiring diagram for a single exciter ignition circuit The single exciter is able to drive both spark plugs Figure 2 Sing...

Страница 17: ...quence The figure below shows how the start run selection can be accomplished using a momentary toggle switch Figure 4 Start Run Switch Wiring Start Contactor The start contactor is used to engage the...

Страница 18: ...alve s pin A as shown below Figure 6 Normal Interrupter Wiring The alternative way on the other hand activates the interrupter valve by grounding pin V instead as shown below Figure 7 Alternative Inte...

Страница 19: ...recommend incorporating a LIMIT ENABLE switch as shown below This switch allows the pilot to remove any doubt that the TSLM may be activating the EHT valve when it is not supposed to Figure 8 EHT wiri...

Страница 20: ...annunciator system Figure 10 Status Light Wiring Exceed Light The TSLM drives another annunciator or panel light in the cockpit as shown in the following diagram Though not absolutely necessary we do...

Страница 21: ...nerator Speed Sensing N1 The diagram below shows the connection of the N1 tach generator to the TSLM The tach generator signal is strong enough to be shared with other instruments Figure 13 Gas Genera...

Страница 22: ...ate but non intrusive measurement Walter M601 type E 11 engines are equipped with 4 ITT wires 2 for main instrumentation and 2 for an electronic limiting unit For conformity we recommend connecting th...

Страница 23: ...ey can be incorporated with similar sensors for other instrumentation by T pieces They will thus provide transducer and measurement redundancy Figure 17 Torque Oil Pressure Sense Wiring We use 4 20mA...

Страница 24: ...il Temp measurement enable setting to 1 in order to enable this measurement Figure 18 Oil Temperature Sense Wiring Sharing thermocouples with a temperature gauge is not a problem Though thermocouples...

Страница 25: ...2 15 N2 VOLT 3 16 TORQUE OIL PRESS 4 17 OILT CAN H 5 18 CAN L BETA 6 19 RUN EXCEED 7 20 START EHT 8 21 STATUS ICONTACTOR 9 22 IGNITION B IINTERUPTER 10 23 EHT IIGNITION A 11 24 POWER POWER 12 25 OILT...

Страница 26: ...ties of the TSLM See Adjusting the Configuration about how to alter any of these settings History Recorded bytes This property tells you how much bytes have been recorded in the TSLM history log Start...

Страница 27: ...e batteries the lower this value Last Attempted Start Max ITT C This value provides feedback about the performance of the last start by telling you what the highest ITT value was during the previous s...

Страница 28: ...01D 1 M601E 11 2 M601E 11A You select the type of M601 engine you have here This setting is used by the TSLM to know what exceed levels to trigger on Set to 0 if you have the M601D Set to 1 if you hav...

Страница 29: ...terrupter check To troubleshoot the interrupter circuit this diagnostic test will toggle the power to the interrupter valve through the TSLM You can now listen for sound etc EHT valve check To trouble...

Страница 30: ...h its dedicated 9 pin maintenance connector the TSLM can link with your computer laptop connecting either directly to your computer s serial port or via a USB to Serial converter Plug in your USB to S...

Страница 31: ...ant to update Only if you select Yes it will update the particular unit to the new version A synchronize will also make SetView read the TSLM s configuration as well as those for the other VR units in...

Страница 32: ...system will take a second or two to enable configuration adjustment as shown below To modify any specific configuration item scroll to the item and hit SPACE BAR or double click on it A dialog box wil...

Страница 33: ...file Diagnostic test and troubleshooting Diagnostic tests are designed to verify the correct installation of the TSLM system and the proper operation of some system components This is strongly recomme...

Отзывы: