TSLM - M601 Operational & Install Manual
Oil Temperature Offset Calibration
This configuration property calibrates the oil-temperature measurement.
Alternative Interrupter Activation
If set to 0, the interrupter will be normally activated (positive voltage out on pin).
If set to 1, the alternative interrupter activation will be employed (pin is grounded).
This value defaults to zero for unit serial numbers 7001 and above.
See also
Start Interrupter Valve circuit
.
Enable Oil-Temperature Measurement
Set to 1 if you want the TSLM to measure and share the Oil-temperature with other devices. See
also
Oil Temperature sensing circuit
.
Torque sensor is 200 psi type
Set to 1 if you are using a 200 psi torque sensor instead of the normal 250 psi sensor. See also
Torque sensor circuit
.
Force a Start sequence when double-clicking Start Button
If set to 1, a start sequence can be forced (by bypassing certain pre-start checks) by “double-
clicking” the START button / toggle switch. The only check that would not be bypassed is the EHT
check. See also
Initiating a Start
.
If set to 0, this feature will be disabled.
Walter Engine Type (0=M601D, 1=M601E-11, 2=M601E-11A)
You select the type of M601 engine you have here. This setting is used by the TSLM to know what
exceed levels to trigger on. Set to 0 if you have the M601D. Set to 1 if you have the M601E-11. Set
to 2 if you have the M601E-11A. See also
Parameter Exceeds
.
Start ITT Control Setting
This value can be adjusted in the range from 580 to 640. It sets the level of limiting for the start.
The lower the value, the lower your start ITT, though your start durations may increase.
History Logs Operations
History retrieval
The TSLM history logs are automatically retrieved when you perform a
synchronize
through the
SetView program. Alternatively these logs can be retrieved via the VRX multi-function display using
it's menu to generate a history file on an inserted USB disk (stick).
History clearance
The history logs are erased from the TSLM memory automatically after a successful retrieval when
using the SetView program. On the other hand via the VRX display clearance of the history must
be confirmed by the user after a successful retrieval.
Viewing the history
History can only be viewed through the SetView software. A history file retrieved onto a USB disk
via the VRX display can be opened from within SetView. See also
Opening and Viewing History
files
.