PRECAUTIONS

 

 
READ this manual BEFORE operating or servicing this unit.  
FOLLOW these instructions carefully.  
SAVE this manual for future reference.  
 
 
 
 

 

 
 
 
 
 
 

DO NOT allow untrained personnel to operate,  

 

clean, inspect, maintain, service, or tamper with  

 

this unit. 

 
 
 
 
 

INTENDED USE 

 
KxxD (-D) line of load cells are intended for industrial systems. Its basic function is force 
measuring or weighing applications. The strain gauge bridge output wiring is connected to 
an overall measurement system. 
 
 
 
 

Changes to current manual version 

Detailed application, intrinsic safety and functional safety information added. 
 
 
 

 

WARNING  
Only qualified personnel are permitted to install and service this unit. 
Exercise care when making checks, tests and adjustments  
that must be made with power on.  
Failing to observe these precautions could result in bodily harm.  

Содержание BLH NOBEL

Страница 1: ...Single channel Load cell KOSD KIMD KISD Double channel Load cell KOSD D KIMD D User manual...

Страница 2: ......

Страница 3: ...4 Load cell ATEX Label 4 Functional safety 5 Electrical connection and supply voltage 6 Load cell connection 7 Application examples 7 Mechanical installation and maintenance 8 Mechanical data 8 Append...

Страница 4: ...trial systems Its basic function is force measuring or weighing applications The strain gauge bridge output wiring is connected to an overall measurement system Changes to current manual version Detai...

Страница 5: ...it individually The two separate electrical circuits are insulated from each other The following KxxD D load cell configurations are available Single bridge load cell with connector or cable connectio...

Страница 6: ...wo 4 pin connectors or dual cable connections KxxD D with one 4 pin connector and single cable connection These load cells are approved for use in an explosive hazardous area provided that suitable in...

Страница 7: ...5X Issue 2 see appendix 2 Functional safety T V 968 FSP 1462 00 17 see appendix 2 Environmental conditions PARAMETER Min Typ Max UNIT Environmental protection IP rating IP67 Operating Temperature Tamb...

Страница 8: ...cific model They can be ordered either with a cable connector or with an integrated cable The safety description is labelled on the load cell For the D version the safety description and connection is...

Страница 9: ...48 year Maximum performance level PL d The achievable performance level assumes that the double channel load cell shall be connected to an overall measuring instrument in a category 3 structure with a...

Страница 10: ...ve gas dust or mining area only trained personnel may perform dimensioning of cables and barriers A descriptive system document should be prepared by the system designer Deviations may occur in custom...

Страница 11: ...cell KxxD D used in hazardous area is shown below The cable shield is not connected to the load cell body and shall be connected in the other end Connection to barrier or isolating IS unit is shown i...

Страница 12: ...revent the cylindrical load cell body from rotating in the supports Standardized adapters for some load cell types are available others can be custom designed and produced by Vishay Nobel On request t...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...IECEx web site http iecex iec ch Certificate number IECEx BAS 14 0015X Issue No 2 Function safety Certificate The functional safety certificate for the KxxD D Load cell can be found on T V Rheinland...

Страница 18: ...Box 423 SE 691 27 Karlskoga Sweden Phone 46 586 63000 Fax 46 586 63099 blhnobel se vpgsensors com www blhnobel com Document no 35218 Publication 600659R7 Vishay Nobel AB 2020 02 17 Subject to changes...

Отзывы: