Installation Guidelines for optimum EMC performance
•
VCCS300 units should be mounted within a metal enclosure using the mounting fixtures provided.
(See “Mechanical Dimensions & Mounting” section)
•
If the application enclosure is not metal, then a metal ground plate should be used to mount both the power supply and the load.
•
Both input and output cables should be fixed as close as possible to the ground plate or metal enclosure.
•
Input and output cables should be separated as much as possible from each other or a shield/screen used to isolate RF currents
•
All cables lengths and loop areas should be minimised.
•
Where cables must enter or exit the enclosure, good high frequency 100nF decoupling capacitors of sufficient voltage rating should be connected to the
cables as close to the entry/exit point as possible.
For further details or assistance contact Vox Power.