background image

 

NEVO+600 Series 

INSTALLATION MANUAL 

_____________________________________________________________________________________________________ 

Page 1 of 4

     

Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland | T +353 1 4591161 | 

www.vox-power.com

 

 

 

 

PLEASE READ THIS INSTALLATION MANUAL CAREFULLY BEFORE INSTALLING THIS PRODUCT AND KEEP THIS MANUAL FOR FUTURE REFERENCE. 

 

All specifications are believed to be correct at time of publishing. Vox Power Ltd reserves the right to make changes to any of its products and to change or improve any part of the specification, 
electrical or mechanical design or manufacturing process without notice.  Vox Power Ltd does not assume any liability arising out of the use or application of any of its products and of any information 
to the maximum extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any products of Vox Power Ltd.  
VOX POWER LTD DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF SUITABILITY, FITNESS 
FOR PURPOSE, MERCHANTABILITY AND NONINFRINGEMENT.  
Please consult your local distributor or Vox Power directly to ensure that you have the latest revision before using the product and refer to the latest relevant user manual for further information relating 
to the use of the product. Vox Power Ltd products are not intended for use in connection with life support systems, human implantations, nuclear facilities or systems, aircraft, spacecraft, military or 
naval missile, ground support or control equipment used for the purpose of guidance navigation or direction of any aircraft, spacecraft or military or naval missile or any other application where product 
failure could lead to loss of life or catastrophic property damage. The user will hold Vox Power Ltd harmless from any loss, cost or damage resulting from its breach of these provisions. 

 

 

Important installation information 

This NEVO+600 series of configurable power supplies are intended for use within end customer applications which restrict access to un-authorized personnel. The instructions in this manual and all 
warning labels on the product must be adhered to carefully. 

 

SAFETY 
 

The NEVO+600S/SL and NEVO+600M/ML series are designed in accordance with the relevant safety requirements of IEC/EN/UL/CSA 62368-1, IEC/EN/UL/CSA 
60950-1, IEC/EN/UL/CSA 60601-1, Low voltage Directive LVD 2014/35/EU and EMC directive EMC 2014/30/EU.  All NEVO+600 series power supplies must be 
installed correctly in a controlled environment which restricts access to any un-authorised personnel. Equipment and system manufacturers must protect 
service personnel against unintentional contact with the output terminals. 

HAZZARDS 
 

Dangerous voltages are present within the power supply. 
It should only be handled by qualified personnel when the power supply has been disconnected from the mains supply voltage for more than 3 minutes.  
External surfaces of the power supply may become extremely hot during and after operation. Appropriate care should be taken.  If series and/or parallel 
combinations of outputs exceed safe voltage and/or energy levels, the final equipment manufacturer must provide the appropriate protection for both users 
and service personnel.  

DE-RATINGS 
 

Ambient 
Temperature 

 

The input module power must be de-rated by 2.5%/°C above 50°C ambient up to a maximum ambient temperature of 70°C. 

Input Voltage 

 

Standard & Medical (S/M) - The input module power must be de-rated by 4.28W/V

RMS

 below120 V

RMS

 (600W @ 120 V

RMS

, 450W @ 85 V

RMS

 

Low Noise (SL/ML) - The input module power must be de-rated by 3.21W/V

RMS

 below120 V

RMS

 (450W @ 120 V

RMS

, 338W @ 85 V

RMS

Remember to take the appropriate de-rating into consideration before specifying any NEVO+600 power supply for an application. 
If in any doubt, please contact Vox Power directly or your local Vox Power representative. 

HEALTH AND SAFETY  

To comply with section 6 of the health and safety at work act, a label that is clearly visible to service personnel must be placed on the final equipment. These 
labels warn that surfaces of the power supply may be hot and should not be touched when the product is operating.  

FUSING 

The power supply has internal single pole fusing in the L (Live) line. 
Fuses are not replaceable. Damaged units should be returned to Vox Power for analysis and repair. 
For Medical (60601-1) installations, the end application should provide an appropriately rated external fuse in the Neutral line. 
DC operation is not covered by safety approvals. Contact Vox Power for details. 

SERVICING 

The power supply contains no user serviceable parts. Repairs must be carried out by authorised personnel only. 
Contact Vox Power for further information. 

APPROVAL 
LIMITATIONS 

NORTH AMERICA - When this product is used with 180V

AC

–253V

AC

 mains where no neutral is present, connect the two live wires to L (Live) and N (Neutral) on the 

input connector. 

COOLING 

For proper cooling of the power supply, the air intake and outlet must not be impeded. Allow 50mm clearance at both ends and position cabling appropriately.

 

EARTH TERMINAL 
MARKING 

To comply with the requirements of IEC/EN/UL/CSA 62368-1, IEC/EN/UL/CSA 60950-1 & IEC/EN/UL/CSA 60601-1, where the incoming wiring earth is intended 
for connection as the main protective earth conductor and where the terminals for such a connection is not supplied on a component or subassembly, the user 
shall add an appropriate label displaying a protective earth symbol in accordance with IEC60417-5019 (2006-08)

 

directly adjacent to the terminal. The label 

should be durable and legible and should withstand the 15 second rub test as per UL60950-1 section 1.7.15. 

WARRANTY 

Contact your sales agent or Vox Power for product repairs. See Vox Power standard terms and conditions for warranty conditions.  

PRODUCT LABELS 

The external product label contains information relevant to the power system. The label contains input voltage, maximum input current, input frequency, 
maximum output power, fuse rating and type, serial number, approvals and product part number in form NEVO+600xx-yyyy-zzz. 

NEVO+ OUTPUT 
MODULES 

Each output module label contains information relevant to that output.  The label contains voltage adjustment range, maximum output current, serial number, 
approvals and the part number in format OPx. 

OTHER 

 

A label warning that external surfaces are hot during operation and that the unit should be allowed to cool down properly should be placed on the unit 

where such a label is clearly visible. 

 

The NEVO+600 series is designed to comply with EMC standards but it does not imply that the end system will comply.  

 

To prolong the life of the unit, use in dust free environment. 

 

Units can sometimes be damaged during transit. In the event of transit damage, DO NOT connect power to the unit.  Contact your sales agent or Vox 

Power. 

 

Always use adequately sized cables and ensure good crimp connections. Use cable supports to minimise stress on connectors. 

 

Avoid excessive shock or vibration. 

 

 

 

 

 

 

 

 

Содержание NEVO+600 Series

Страница 1: ... rated by 2 5 C above 50 C ambient up to a maximum ambient temperature of 70 C Input Voltage Standard Medical S M The input module power must be de rated by 4 28W VRMS below120 VRMS 600W 120 VRMS 450W 85 VRMS Low Noise SL ML The input module power must be de rated by 3 21W VRMS below120 VRMS 450W 120 VRMS 338W 85 VRMS Remember to take the appropriate de rating into consideration before specifying ...

Страница 2: ...150mV 24mV 48mV 240mVPP 0 5 ABCDEFGH Note 1 Output module 30 C base 100 load SR332 issue 2 Method I Case 3 Ground Fixed Controlled Note 2 Note 3 A Remote Sense B External Voltage control C External constant current control D Current output signal E Current share F Over Voltage protection G Over temperature protection H Dual Slot module Can only be used with NEVO 600 chassis with date codes from 20...

Страница 3: ...Dimensions and Mounting SCREWS Location Details Penetration Tightening Output Module Mount 2 per module M3 POZI CSK 5mm max length 0 5NM Input module Mount MH1 3 Bottom MH4 5 Side M4 4mm max including chassis 0 5NM Top Cover Mount 5x M3 POZI CSK 1x M2 5 POZI CSK 5mm max length 4mm max length 0 5NM Unless stated otherwise all dimensions are in millimetres and in accordance with DIN2768 1 2 CLASS C ...

Страница 4: ...Tab Size 6 35x0 8mm VARIOUS 2 VARIOUS J5 Output Signals 6 PIN 1 25mm with Friction Lock 28 30AWG MOLEX 2 1510210600 50058800 Notes 1 Terminal and wire current rating must exceed maximum short circuit output current Eg Output 1 25A 1 25 31 25Amps 2 Direct equivalents may be used for any connector parts 3 All cables must be rated 105 C min equivalent to UL1015 4 Pinout is for single output types onl...

Отзывы: