--8--

 

Connection Input Commutation to Mains: 

 

 

An IEC power socket is located at the unit's front panel, which is labelled with 

"IN 230 V AC max. 10 A"

. Use the delivered 

IEC power cable to connect the unit to a 230 V shockproof socket, which is supplied with external mains voltage (country 
current) over the current supply at the vehicle. In case of vibration load, the connection cable should be secured near the 
unit (strain relief, cable clips etc.)

 

 
 

Start-up and Operation:

 

 

After the connection of the inverter to the 12 V battery, the inverter is ready for operation.  
The unit is switched-on by momentarily pressing the ON/OFF switch (ON) at the display panel of the inverter (ON). The 
green light-emitting diode (LED) 

„INVERTER“

 indicates the readiness for service. After an internal self-test of the entire 

system being indicated by 2 short beeps and one long beep, the inverter operation starts. 230 V alternating voltage (AC) is 
now supplied to the unit socket at the front panel for supply of the consumers. 

 

 

Operation of the Inverter in Automatic Mode (Stand-by Mode): 

 

The automatic mode helps to save battery energy in case of larger consumers.  Very often, large consumers are switched-
on for a short moment or in intervals due to their high power consumption, but the inverter permanently loads the battery, 
even if the consumer has already been switched-off (idle time)!!

 

 

This unnecessary battery load can be reduced by use of the stand-by function! 

 

The inverter is started in 

automatic mode

 by momentarily pressing the ON/OFF switch, and the LEDs 

"INVERTER" 

and 

"AUTOM."

 will be lighting. 

 

When being switched-on, the inverter checks the connected load continuously (e. g. TV-set). So, capacity is required, as 
long as the TV-set is switched-on (> 15 W, see below Adjustment of the Threshold). If the TV-set will be switched-off (< 15 
W), the inverter will recognize this state, and it changes automatically to stand-by mode after a short observation time.

 

All light-emitting diodes will stop lighting, only the yellow LED 

„AUTOM.“ 

will be flashing every second. Now, the battery 

load is reduced to approx. 0.4 A. 

 

The inverter checks every second, if any load (> 15 W) has been connected to the output. If the inverter does not find a 
consumer within the following 5 or 10 minutes (duration of the search is adjustable) during the stand-by mode, it will be 
switched-off completely, and it can only be restarted by means of the ON/OFF switch (safety measure).

 

 
Optimum adaptation of the stand-by mode to the corresponding 
requirements is achieved by setting the stand-by threshold (load) as well as 
the duration of the stand-by search (time). Remove the display panel from the 
front panel and use the two switches for setting: 

 

 

Switch 1 (Load):  Threshold 15 W or 60 W

 

Switch 2 (Time):  Duration of the search, 5 minutes or 10 minutes

 

Switch 3 (PowerSave):   If desired by remote control

 

 

 

can be switched-on/off or permanently  

 

 

 

off 

Switch 4 (Run Mode): 

Operation by means of display panel /

 

  

 

remote control or continuous operation

 

  

 

 

During the stand-by mode, the inverter is not completely switched-off!! 

 

 
When being set to RunMode "Always On", the inverter can start automatically!!!

 

It is therefore imperative to always separate the inverter from the 230 V consumers or the installation 
prior to execution of work at the 230 V consumers or the installation belonging to it! 

 

 

Содержание MobilPOWER SMI 600 Sinus

Страница 1: ...l for power saving with automatic disconnection which ensures minimised power consumption during idle time An integrated undervoltage protection protects the batteries by disconnecting the inverter in case of dropped battery voltage An additional special feature of the MobilPOWER Inverter Sinus NVS is the integrated mains priority control One of the special advantages of this commutation to mains ...

Страница 2: ...y for insulation faults points of break or loosened connections Occurring defects must be remedied immediately The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric system If the non commercial end user is not able to recognize the characteristic values being valid for a unit or the regulations to be observed a specialist is always to...

Страница 3: ... 10 16 mm is possible In this case the screwed connection between the original cable and the extension should be sound Always protect and cover this screwed connection because of the risk of short circuit The connection of the battery cable for the inverter should always be made with C O R R E C T P O L A R I T Y Wrong polarity might result in destruction of the unit A unit failure due to wrong po...

Страница 4: ...safety relay ensures that the inverter cannot be restarted before the country current is removed Restarting of the inverter requires pushing the ON OFF switch at the display panel The LED Line will stop lighting and the LEDs Inverter and Autom will be lighting By this the user recognises that the 230 V consumers are now supplied by the inverter The integrated commutation to mains allows a load up ...

Страница 5: ...ontrol The consumer will be connected at the shockproof socket OUT of the unit The connection to the current supply at the vehicle is effected by insertion of the delivered mains cable into one of the mains sockets 1 and on the other side into the IEC power socket IN at the inverter ...

Страница 6: ...lled and the connection of the earth bolt at the inverter with the potential equalization cable 4 mm green yellow to the main earth terminal of the vehicle serves as protection from possible insulation faults of the connected units The connection to the current supply at the vehicle is effected by insertion of the delivered mains cable into one of the mains sockets 1 and on the other side into the...

Страница 7: ...ditional potential equalization cable Furthermore the terminal screws N1 and PE at the inverter will be connected with a short insulated piece of wire 2 5 mm serving as earth bridge and the earth bolt and the potential equalization cable 4 mm green yellow will be connected to the main earth terminal of the vehicle The connection to the current supply at the vehicle is effected by insertion of the ...

Страница 8: ...d AUTOM will be lighting When being switched on the inverter checks the connected load continuously e g TV set So capacity is required as long as the TV set is switched on 15 W see below Adjustment of the Threshold If the TV set will be switched off 15 W the inverter will recognize this state and it changes automatically to stand by mode after a short observation time All light emitting diodes wil...

Страница 9: ...the nominal capacity of the inverter 300 600 W Please observe that the real current consumption of many 230 V household appliances is higher than the value resulting from the active power which is indicated in W on the nameplate It is also to be considered that almost all appliances are requiring a higher capacity during the starting phase moment of starting than during the normal operation The st...

Страница 10: ...ory C The inverter has recognized an excessive load or load jump Load jumps or high starting current rates are always an extreme load for the inverter In order to prevent damage of the inverter by these characteristics the inverter being already heated by load will be switched off earlier than an inverter being cold As long as the LED INVERTER is flashing the inverter has not been cooled down suff...

Страница 11: ... 2067 Technical Data SMI 300 Sinus NVS SMI 600 Sinus NVS Nominal Voltage Lead Acid Gel AGM Battery DC 12 V 12 V Nominal Voltage Lithium LiFePO4 Battery DC 12 V 13 3 V 12 V 13 3 V Input Voltage DC 10 5 V 15 5 V 10 5 V 15 5 V Recommended Minimum Battery Capacity 60 Ah depending on consumer 80 Ah depending on consumer Connection Cable Battery 2x 4 mm2 1 2 m length 2x 10 mm2 1 2 m length Recommended F...

Страница 12: ...Cable Length 2 m Installation and Operating Manual Control Cable 5 m Length for Operation of the Display Panel as Remote Control Available Accessories Control Unit Order No 2065 Extension Set with Second Remote Control Order No 2067 Fuse holder for strip fuse Order No 2242 For SMI 300 Sinus NVS Strip Fuse 40 A Order No 2244 For SMI 600 Sinus NVS Strip Fuse 80 A Order No 2247 Subject to misprints e...