--7--
Connection Plan 3:
Operation of Several Consumers in Fixed Installed System at the Inverter with Mains
Priority Control:
The fixed installed consumer sockets "2" are connected to the shockproof socket "OUT" of the inverter and, according to
standards, is led over a fault current breaker (FI, 30 mA) and is equipped with an additional potential equalization cable.
Furthermore, the terminal screws "N1" and "PE" at the inverter will be connected with a short insulated piece of wire
2.5 mm² serving as "earth bridge", and the earth bolt and the potential equalization cable 4 mm² green/yellow will be
connected to the main earth terminal of the vehicle.
The connection to the current supply at the vehicle is effected by insertion of the delivered mains cable into one of the
mains sockets "1" and on the other side into the IEC power socket "IN" at the inverter.