How to set the operating modes:

 

 
The micro slide switches for adjustment of the operating modes are located at the inverter behind the control panel. 
 
The functions of the ON/OFF control unit can only be used, if

 microswitch 4

 (Run Mode)      

 had been placed to position 

Always On.

 

 
 

Microswitch 3 

(Power Save) is used to  

switch the Power Save Mode on or off (see operating manual 
inverter). 

 
In connection with the ON/OFFF control unit, 

microswitch 2

 (Power Save Time) has no function. 

 

Microswitch 1

 (Power Save Load) is used to set the thresholds for 

operation in Power Save Mode between  
25 W and 60 W (see operating manual inverter). 
 
 
 
  
  

 

 

     View: Display panel removed 

 

 
 
 

 
 
 
 
 
 
 
 
 
 

 

 

Disposal of 
the product 
in the 
household waste 
is not 
allowed.

 

The product 
conforms to RoHS.  
Thus, it complies 

with the directives for Reduction of 
Hazardous Substances in Electrical and 

Electronic Equipment

.

 

 

 

 

Declaration of Conformity  

According to the stipulations of the regulations 2006/95/EG, 2004/108/EG, 95/54/EG this product corresponds to the  
following standards or standardized documents: 
EN60950;  EN 55014 ;  EN55022 B;  DIN14685;  DIN40839-1;  EN61000-4-2;  EN61000-4-3;  EN 61000-4-4 

 

 
 
 
 
 
 

 
Subject to misprints, errors and technical modification without notice. 
All rights reserved, particularly the right of reproduction. Copyright 

 VOTRONIC 04/14. 

Made in Germany by VOTRONIC Electronic-Systeme GmbH & Co. KG, Johann-Friedrich-Diehm-Str. 10, 36341 Lauterbach/GERMANY 

Phone: +49 (0)6641/91173-0     Fax: +49 (0)6641/91173-20   E-Mail: [email protected]     Internet: www.votronic.de 
 

Technical Data:  

 

Nominal Voltage (DC):

 

 

12 V / 24 V  

Control Input, max. Voltage: 

32 V 

 

Control Input (ON Recognition): 

from 10 V to 32 V  

Control Input (OFF Recognition):

 

less than 1.0 V 

Dimensions (mm):

 

75x47x20 

Weight:

 

 

40 g 

Ambient Conditions, Humidity of Air:

 

max. 95 % RH, no condensation 

Delivery Scope:

 

Available Accessories: 

 

ON/OFF Control Unit

 

- Connection Cable,  5 m Length, as Extension, Order No. 2005 

 

Connection Cable, 6-Poles, Length 30 cm

 

 

 

 

 

 