Assembly instructions VOSS quick connect system 246
NX
, page 15 of 18
4.3. Disassembly
Before disconnecting, the line must be free of pressure.
Step 1
To make disassembly easier, the retaining element can rotate
and be set into 8 different positions.
Fig. 27
Step 2
Press the corrugated segment of the retaining element to
open.
Fig. 28
Step 2, example no. 1
Observe the corrugated segment below the tube.
Release with index finger.
Fig. 29
!