INSTALLATION OPERATIONS AND MAINTENANCE MANUAL - RXC/Hi SERIES
Fam. / Type
Serial Number
Power Supply
Refrigerant type
Wiring diagram n°
Refrigerant Charge:
Circuit 1
CO2 eq.
LOW PRESSURE SIDE
Working Pressure
Working Temperature
Min Design Temperature
Max Design Temperature
Year Build
Operating Weight
Max. Current Input
Auxiliary voltage
Motor Power Input:
Supply Fan
Return Fan
Compr. Circ. 1
HIGH PRESSURE SIDE
Working Pressure
Max Design Pressure
Min Design Temperature
Max Design Temperature
Safety Pressure
“Hermetically sealed equipment. It contains fluorinated greenhouse gases covered by the Kyoto protocol”
VORTICE INDUSTRIAL S.r.l. - via B. Brugnoli, 3 - 37063 Isola della Scala - Verona (Italy) Tel. +39-045 6631042 - www.vorticeindustrial.com
Fabbricato in Italia - MADE IN ITALY
kg
A
kW
kW
kW
bar
bar
°C
°C
bar
kg
t eq
bar
°C
°C
°C
(V/Hz/ph)
GWP
0426
CAPTION:
(1)
Unit model and size
(2)
Serial number
(3)
Power supply characteristics
(4)
Type of refrigerant
(5)
Wiring diagram number
(6)
Manufactured year
(7)
Overall unit weight
(8)
Max. electric current consumption
(9)
Auxiliary voltage
(10)
Refrigerant content in the circuit 1
(11)
CO
2
equivalents
(12)
Electric power input on supply fan
(13)
Electric power input on exhaust fan
(14)
Electric power input on circuit 1 compressor
(15)
Working pressure
(low pressure side)
(16)
Working temperature
(low pressure side)
(17)
Min design temperature
(low pressure side)
(18)
Max design temperature
(low pressure side)
(19)
Working pressure
(high pressure side)
(20)
Max design pressure
(high pressure side)
(21)
Min design temperature
(high pressure side)
(22)
Max design temp. (gas)
(high pressure side)
(23)
Max design temp. (liquid)
(high pressure side)
(24)
Safety pressure
(high pressure side)
In all dealings with the Company it's essential to quote the
model and serial number indicated on this plate (ref. 1 and 2).
1
2
3
4
6
7
11
8
5
9
12
13
14
15
16
17
18
19
20
21
22
23
24
10
1.9 Limits of use and prohibited uses
The machine has been designed and built exclusively for the uses described in the technical manual.
Any other use is prohibited as it could generate health risks for the operators and users.
However, the unit is not suitable for operation in environments:
• where vibrations are present;
• where electromagnetic fields are present;
• where aggressive atmospheres are present.
THIS UNIT IS NOT SUITABLE FOR OPERATION IN EXPLOSIVE ATMOSPHERE.
1.10 Unit identification
Each unit has a label attached to the outside of the unit, which shows the identification data of the machine together with the
main technical characteristics.
For electrical information not included on the label, refer to the electrical diagram.
Check that the characteristics of the electrical network comply with the data on the identification plate.
The identification label must never be removed from the unit.