43
"Holiday" Function
Special mode of operation: manually enabled and useful if the user leaves the room for a longer period of time.
Operation includes:
- fixed "30% less than the Minimum ” speed (no other speeds, no OFF equipment);
- environment sensors not enabled (remote inputs not actived);
- bypass always closed.
When the mode is active, the message "Holiday" appears on the display: see "Home Page" in the "Operation
and Use" section.
NOTE: Activating the Mode “Holiday” will be deactivate other product functionings/selections.
To re-activate other product functionings/selections, need to deactivate the Mode “Holiday” before.
For more details on how to activate / deactivate the function, see "Activating / deactivating Holiday" in the
"
Operation with remote control display
".
“By-Pass MAN” Function
Special mode of operation: manually enabled and useful if you want to force air replacement without heat
recovery.
The operating principle is the same as: "By-Pass" function.
NOTE: If manually enabled, the “By-Pass MAN” function will remain active for 12 h. After this period, the “By-
Pass MAN” function will come back to: Not enabled.
NOTE: (In case of “By-Pass MAN” Enabled) However you can manually deactivate the function, setting “NO”
on “By-Pass MAN Menu”. After Deactivating, the operating principle will be come back the same of “By-Pass”
function.
NOTE: In case of “No-Frost” function active, you can not manually activate the “By-Pass MAN” function.
When the function is active, the message "By-Pass" flashing appears on the display: see "Home Page" in the
"Operation" and use ". For details on how to activate/deactivate the function, see "Activating/deactivating By-
Pass MAN" in the paragraph "Operation and Use".
"Quiet" Function
Special mode of operation: manually enabled and usefull if the user needs a certain period during the day
where the heat recovery unit needs to emit low noises (For example during the night).
ENGLISH