16
Replacing the VX-1 Bungee Shock Cord
Step 2
. Move the rowing handle
from the S-Bend handle catch to a
point where it is resting on top of the
tank . This helps line up the Bungee
Cord hole for easier removal/
replacement. Detach Bungee Cord
from lower rear attachment point.
Step 3
. Unwrap the
Bungee Cord from all
of the Bungee Pulleys.
Step 1
. Remove the Perspex
cover from rear of upper frame.
Disconnect sensor lead
before removing cover
completely.
Step 4
. Next, remove the magnetic ring. To
loosen the Rear Mainshaft Bolt holding the
magnetic ring in place, it is necessary to keep
the mainshaft and impeller assembly from turn-
ing with the bolt. Open the yellow tank plug
and insert a wrench wrapped in a lint free cloth
(to protect the electroplating finish on the
blades) to catch the impeller blade and allow
the Rear Mainshaft Bolt to be loosened as
shown below right with a 6mm Allen key.
Caution:
Do not allow a dissimilar metal to
directly contact the impeller blade. Premature
rusting could occur . Cover any tool inserted
the tanks with a lint free cloth and keep fingers
clear.
Capture impeller blade using tool covered with a
lint free cloth and a 6mm Allen key to remove
Rear Mainshaft Bolt as show right
Rear Mainshaft Bolt and
Magnetic Ring
WARNING
Do not insert fingers into tank!