SAFE USE WARNING—To reduce risk of fire, electrical shock and 

injury to persons, observe the following:

-   Use this heater only as described in this manual. Any other use not 

recommended by the manufacturer may cause fire, electric shock, or 

injury to persons.

-   Extreme caution is required at all times a heater is in operation. 

Always unplug heater when not in use. Vornado does not 
recommend unattended and unsupervised use of this heater. 

-   This heater is hot when in use. To avoid burns, do not let bare 

skin touch hot surfaces. If provided, use handles when moving 
this heater. 

-   Always plug heaters directly into a wall outlet/receptacle. Never use 

with an extension cord or relocatable power tap (outlet/power strip). 

Do not use this heater on a surge-protected unit or Ground Fault 
Circuit Interrupted (GFCI) outlet. Note: GFCI outlets are typically 

found in bathrooms and kitchens and feature a “reset” button to 
prevent tripping of an electrical circuit. 

-   Before plugging power cord into electrical outlet, be sure that 

all electrical information on the rating label, including voltage, is 
compatible with your outlet’s power supply. 

-   

WARNING: 

To reduce likelihood of circuit overload, fire and electric 

shock, do not operate with a solid state speed device, such as a 
dimmer control switch. Use of this appliance on the same electrical 
circuit as another high energy use product, such as a vacuum 
cleaner, blender, variable speed fan or circular saw is not advised. 
Do not use this heater with a timer designed to automatically turn 
the unit on or off, as this may accidentally disable the heater’s 
thermal cutout safety feature. 

-   Risk of fire. Do not operate if it has been dropped or if damage is 

apparent to any part of the unit including the cord and plug. Only 
original replacement parts may be used. 

-   Never use the cord as a handle or otherwise yank, strain or stretch 

the power cord. 

-   While the product is plugged in, do not insert or allow foreign 

objects to enter any ventilation or exhaust opening as this may 

cause an electric shock or fire, or damage the heater.

-   Check your heater cord and plug connections. A loose fitting outlet 

can cause the plug to overheat or cause a fire. Be sure plug fits tight 

in the outlet. Check frequently during use to make sure plug and 
outlet are not hot. If so, discontinue using heater and have outlet 

replaced by a qualified electrician.

-   Never ignore the signs of an electrical problem, such as: warm 

outlet coverplates, sparks when plugging in or operating, lights 

flickering/dimming during operation. Immediately turn off and 

unplug the appliance if any such problems are noticed. Contact a 

qualified electrician to investigate possible causes before operating 

the appliance again. 

-   

Note:

 Heaters draw more current than small appliances, 

overheating of the outlet may occur even if it has not occurred with 
the other appliances. 

-   This appliance has a polarized plug (one blade is wider than the 

other.) To reduce the risk of electrical shock, this plug is intended to 

fit in a polarized outlet only one way. If the plug does not fit fully in 
the outlet, reverse the plug. If it still does not fit, contact a qualified 

electrician. Do not attempt to defeat this safety feature.

-   Before moving, repositioning, servicing, cleaning and when not in 

use, use the product controls to turn off the power and then unplug. 
To disconnect from outlet, grasp and pull only the plug. Also, power 
off and unplug if the product will be left unattended for an extended 
period of time or during electrical storms. 

-   If your heater suddenly stops working: 

•  This heater is equipped with a thermal cutout safety feature 

Содержание MVH

Страница 1: ...model MVH vornado com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS ...

Страница 2: ...2 English vornado com 800 234 0604 help vornado com we expect this product to be PERFECT if it s not WE will make it right ...

Страница 3: ...3 English Important Safety Instructions 4 Safety Features 7 Controls 8 How to Use 9 Cleaning 10 Storage 11 Reset Heater 11 Troubleshooting 12 Warranty 13 CONTENTS ...

Страница 4: ... not use this heater in an RV boat or during any application where battery power is converted to AC power Place this product at least 3 feet away on all sides from electrical outlets furniture pillows bedding papers clothes curtains and other objects that may cause or catch on fire Do not place the heater near a bed because objects such as pillows or blankets can fall off the bed and be ignited by...

Страница 5: ...ny part of the unit including the cord and plug Only original replacement parts may be used Never use the cord as a handle or otherwise yank strain or stretch the power cord While the product is plugged in do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater Check your heater cord and plug connections A l...

Страница 6: ... CLEANING instructions provided Do not open appliance housing while product is plugged in To avoid risk of shock all service and or repairs must be done by a Vornado Authorized Service Center DISPOSAL WARNING To reduce waste and environmental harm observe the following PACKAGE RECYCLING The packaging protects the appliance from transport damage The packaging materials are selected from the point o...

Страница 7: ...on and power is restored AUTOMATIC SAFETY SHUT OFF SYSTEM If airflow becomes blocked power to heater is shut off to prevent overheating AUTOMATIC TIP OVER PROTECTION If tipped more than 10 degrees in any direction power is cut to heater FINGER FRIENDLY DESIGN Resists curious fingers COOL TOUCH CASE Safe to touch even on high heat setting ...

Страница 8: ...8 English CONTROLS POWER On I Off O THERMOSTAT MODE High Heat III 1500 watts Medium Heat II 1125 watts or Low Heat I 750 watts ...

Страница 9: ...on back of heater for lifting and carrying 2 Position heater so airflow is not obstructed 3 Plug power cord into standard grounded wall outlet 4 Press Power button and select Mode Red light on front of heater illuminates to indicate the heater is On Next set thermostat to highest setting by turning clockwise When room reaches desired comfort level turn thermostat slowly counterclockwise until heat...

Страница 10: ...ccumulated dust off the Front Outlet Grill 3 Use brush attachment on household vacuum cleaner to vacuum any accumulated dust off Air Inlets on sides of heater 4 Wipe down the entire heater with a soft dry cloth You should periodically blow out the heater with pressurized air to keep heat element and motor clear of dust hair and debris that can build up inside the heater as it moves air during use ...

Страница 11: ...cur when the inlets or outlet are blocked If this happens the safety shut off system cuts power to the heater and you must manually reset the heater 1 Power heater off then unplug power cord 2 Remove any obstructions 3 Wait 5 10 minutes allowing heater to cool down 4 Plug in power cord and place heater in desired position 5 Press Power button On Your Vornado Heater should now function normally Not...

Страница 12: ...vel surface See SAFETY FEATURES Unit is damaged or in need of repair Cease usage and unplug Contact Consumer Service for assistance Ensure unit is set to High Heat and thermostat is set to highest temperature setting Close all doors and windows to trap heat Allow unit to fully circulate heat throughout room may take several minutes Press the Power button Off and unplug unit A cylindrical plunger i...

Страница 13: ...fication repair by unauthorized repair center or use of non approved replacement parts is not recommended and any consequences will not be covered by support services or product warranties The product warranty will be honored only on models that are being used in the country intended REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER VORNADO SHALL NOT BE ...

Страница 14: ...CL3 0446 R V03 Vornado Air LLC 415 East 13th Street Andover Kansas 67002 800 234 0604 vornado com ...

Отзывы: