![VOP CeramicMaster E10 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/vop/ceramicmaster-e10/ceramicmaster-e10_user-manual_1050080010.webp)
Ceramic Master E10 en v2
10
DESCRIPTION OF PARAMETERS IN ORDER OF THEIR
APPEARANCE
PROGRAM NAME
IDLE TEMP
PREDRY TIME
DRY TEMP
DRY TIME
FIRE RATE
FIRE TIME
FIRE TEMP
COOL1 TIME
COOL2 TIME
VRUN TEMP
VRUN TIME
VSTOP TEMP
VSTOP TIME
parameter for set the name for the current program.
Choose the position for desired letter by using buttons
and
. Then choose the letter using
MFRK
.
idle temperature. This is the temperature which the
furnace keeps in STOP mode. Its value is from 150°C to
600°C but it can’t exceed (DRY TEMP-20)°C.
during this time the table stays in lower end position
when the temperature in the chamber is equal to
DRYTEMP. It can be changed from 0 s to 1 h.
drying temperature. Its value is from (IDLE TEMP+20)°C
to (FIRE TEMP-20)°C.
the time for moving the table from lower end position to
the medium position which is about 1cm from the upper
end position of the table. The temperature in the
chamber is DRY TEMP. It can be changed from 0s to 1h.
increase rate of the temperature for the firing. Its value is
from 30°C /min to 200°C /min.
time for maintaining the temperature FIRE TEMP. It can
be changed from 0s to 30min.
temperature for the firing. Its value is from
(20)°C to 1100°C.
During this time the table is about 1cm from the upper
end position. It can be changed from 0s to 1h.
time for opening the furnace to the lower end position.
It can be changed from 0s to 1h.
temperature which defines the start of the time VRUN
TIME. Its value is from 0°C to 1250°C. If its value
exceeds the value of the parameter FIRE TIME, vacuum
will never start.
time which defines the start of the vacuum. It starts after
the firing chamber temperature reaches the value of the
parameter VRUN TEMP. It can be changed from 0s to
1h.
temperature which defines the start of the time VSTOP
TIME. Its value is from 0°C to 1250°C. If its value
exceeds the value of the parameter FIRE TIME, vacuum
will never start.
time which defines the stop of the vacuum. It starts after
the firing chamber temperature reaches the value of the
parameter VSTOP TEMP. It can be changed from 0s to
1h.