VOP CeramicMaster E10 Скачать руководство пользователя страница 10

 

 

 Ceramic Master E10 en v2 

 

  10 

DESCRIPTION OF PARAMETERS IN ORDER OF THEIR 
APPEARANCE 
 
 

PROGRAM NAME 

 
 
 

IDLE TEMP 

 

 
 

PREDRY TIME 

 
 

DRY TEMP 

 

 

DRY TIME 

 
 
 
 

FIRE RATE 

 
 

FIRE TIME 

 
 

FIRE TEMP 

 
 

COOL1 TIME 

 
 

COOL2 TIME 

 
 

VRUN TEMP 

 
 
 
 

VRUN TIME 

 
 
 
 
 

VSTOP TEMP 

 
 
 

VSTOP TIME 

 
 

 
 

 
 
 
 
parameter  for  set  the  name  for  the  current  program. 
Choose  the  position  for  desired  letter  by  using  buttons 

 and

. Then choose the letter using 

MFRK

.  

 
idle  temperature.  This  is    the  temperature  which  the 
furnace keeps in STOP  mode.  Its  value is from  150°C to 
600°C but it can’t exceed (DRY TEMP-20)°C. 
 
during  this  time  the  table  stays  in  lower  end  position 
when  the  temperature  in  the  chamber  is  equal  to 
DRYTEMP. It can be changed from  0 s   to 1 h. 
 
drying  temperature.  Its  value  is  from  (IDLE  TEMP+20)°C 
to (FIRE TEMP-20)°C. 
 
the time for moving the table from lower end position to 
the medium position which is about 1cm from the upper 
end  position  of  the  table.  The  temperature  in  the 
chamber is DRY TEMP. It can be changed from 0s   to 1h.  
 
increase rate of the temperature for the firing. Its value is 
from  30°C /min  to 200°C /min. 
 
time  for  maintaining  the  temperature  FIRE  TEMP.  It  can 
be changed from 0s to 30min. 
 
temperature  for  the  firing.    Its  value  is  from  
(20)°C to 1100°C. 
 
During  this  time  the  table  is  about  1cm  from  the  upper 
end position. It can be changed from  0s  to 1h.   
  
time  for  opening  the  furnace  to  the  lower  end  position.   
It can be changed from  0s   to 1h.  
  
temperature  which  defines  the  start  of  the  time  VRUN 
TIME.    Its  value  is  from    0°C    to    1250°C.  If    its  value 
exceeds the  value of the parameter  FIRE TIME, vacuum 
will never start.   

 

time which defines the start of the vacuum. It starts after 
the firing chamber temperature reaches the value of the 
parameter  VRUN TEMP.  It can be changed from  0s    to 
1h.   

 

temperature  which  defines  the  start  of  the  time  VSTOP 
TIME.    Its  value  is  from    0°C    to    1250°C.  If    its  value 
exceeds the  value of the parameter  FIRE TIME, vacuum 
will never start.   

 

time which defines the stop of the vacuum. It starts after 
the firing chamber temperature reaches the value of the 
parameter VSTOP TEMP.  It can be changed from  0s    to 
1h.   

   

Содержание CeramicMaster E10

Страница 1: ...Ceramic Master E10 en v2 1 CeramicMaster E10 USER MANUAL ...

Страница 2: ...rameters in order of their appearance 6 ERRORS AND FOLLOWING ACTIONS 7 IMPORTANT PRACTICAL INFORMATION 8 EXCANGE OF DATA AND FIRMWARE BETWEEN THE FURNACE AND PC Transfer of programs from PC to the Ceramic Master E10 furnace Transfer of programs from the Ceramic Master E10 to PC Transfer of a LOG file from the Ceramic Master E10 furnace to PC Reloading of the control program flash 9 TECHNICAL DATA ...

Страница 3: ...t assistant However inappropriate use may damage the equipment and be harmful to personnel Please observe the relevant safety instructions and read the Operating Instructions carefully We wish you pleasant and fruitful work with the CERAMICMASTER E10 SYMBOLS This symbol indicates that there is high dangerous tension under the bonnet which it is put on This symbol indicates that the machine complie...

Страница 4: ...alter the device the notices and stickers must be kept in good condition so that they are easily readable they should not be removed the machine must not function in case of being damaged and in position to injure the staff or a third person keep the cables out of heat oil and coarse objects do not catch the device by the cable when you move it switch off the furnace and pull out the plug of the f...

Страница 5: ... 2 Ceramic table 3 Lift table 4 Cooling pad 5 Front panel 6 Mains switch 7 Mains fuses 8 Plug of power cord 9 Plug of pump s power cord 10 Fuse for pump 11 Plug of RS232 12 Nozzle of pump s hose 13 Hose of the pump 14 Adapter 15 Vacuum pump 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 ...

Страница 6: ...ing off from the master switch as well as from the contact It is possible to calibrate the temperature T within the limits of plus minus 50 C In order to do this you must proceed with the following steps open the furnace switch it off switch it on again while pressing the buttons RUN and STOP at the same time Now you are in service mode You see the following indication on the display 0 00 00 000 0...

Страница 7: ...ent of the table at any position cancels all changes of the chosen parameter in a programming mode recovers the normal working mode of the furnace after error closes manually the furnace The button can increase decrease the chosen parameter value with 100 by pressing it while turning the multi functional rotary knob opens manually the furnace The button can increase decrease the chosen parameter v...

Страница 8: ...ue in the firing chamber The LINE 2 shows following information MODE sector shows information about current stage TIME sector shows the time left till the end of the executed program Indicator 1 the furnace is in the phase of drying Indicator 2 the furnace is in the phase when the tempera ture increases to the value for firing Indicator 3 the furnace is in the phase of firing Indicator 4 the furna...

Страница 9: ...FRK in order to chose the parameter you want to change Press button RUN in order to chose the value of the parameter you want to change If you have chosen the first parameter you would see on the display XX YYYYYYYYYY EDIT PROGRAM NAME Indicator of the button RUN turns off and the red indicator on the button STOP begins to blink Turn the MFRK to change the parameter value Press button STOP in orde...

Страница 10: ... changed from 0s to 1h increase rate of the temperature for the firing Its value is from 30 C min to 200 C min time for maintaining the temperature FIRE TEMP It can be changed from 0s to 30min temperature for the firing Its value is from DRYTEMP 20 C to 1100 C During this time the table is about 1cm from the upper end position It can be changed from 0s to 1h time for opening the furnace to the low...

Страница 11: ...be able to change the programmed value Button ESC changes parameter FIRE TEMP and button changes parameter FIRE TIME When programming the temperature conditions for parameters IDLE TEMP DRY TEMP and FIRE TEMP the program temperature cannot be lower than this of the previous parameter and at the same time higher than this of the next parameter There is a possibility for fast changing of parameters ...

Страница 12: ...r position sensor for the table is not reached for the required time during opening of the furnace ATTENTION Errors concerning the vacuum 28 The selected vacuum is not reached for the required time 50 There exists residual vacuum during the initial power on procedure 51 After releasing the vacuum for the required time the vacuum is not released entirely 75 The vacuum can not be released in program...

Страница 13: ...cessary to hold the furnace in stand by mode for at least 0 5 hours After switching on the furnace close the dome and wait 0 5 hours 7 If the power supply is interrupted during the working process and a If the temperature in the chamber has not decreased by more than 15 degrees the current program will continue from the stage at which it has been stopped b If the temperature in the chamber has dec...

Страница 14: ... data is needed then start the program Teraterm Pro on the PC Go to menu SETUP Serial Port in this program and perform following settings Com x Serial port number Baud Rate 9600 Data 8 bit Parity none Stop 1 bit Flow Control none Transmit Delay 0ns 1000ms Enter the menu File Send File and perform following settings Options select binary Enter the file name where the programs are to be loaded from ...

Страница 15: ...eeded press the ESC button When you wish to start transfer of data from the furnace to the PC start the program Teraterm Pro Open the menu SETUP Serial Port and perform following settings Com x Serial port number Baud Rate 9600 Data 8 bit Parity none Stop 1 bit Flow Control none Transmit Delay 0ns 1000ms Go to the menu File Log and perform following settings Options select binary Enter the file na...

Страница 16: ...ss the ESC button and following question will appear on the furnace display Log File to PC From the PC start the program Teraterm Pro Enter the SETUP Serial Port menu and perform following settings Com x Serial port number Baud Rate 9600 Data 8 bit Parity none Stop 1 bit Flow Control none Transmit Delay 0ns 1000ms Go to the menu File Log and perform following settings Options binary Enter the file...

Страница 17: ...ace 1 Here the program will count down 10 sec If within 10 seconds the SPACE bar of the PC is not pressed the furnace will exit from the procedure However if the SPACE bar is pressed within 10 sec then the internal program of the furnace will be deleted and the furnace will wait to load the new program which is in HEX format file This is done in the following way In the program Teraterm Pro go to ...

Страница 18: ...ice is designed for usage in normal dental premises up to 2000 m altitude above sea level 13 The maximum relative humidity of the air must be 80 for temperatures up to 31 С decreasing lineally to 50 relative humidity for temperature 40 С 14 Working modes 14 1 Programming mode Programming of the parameters is fully described in chapter 7 PROGRAMMING 14 2 Working mode It shows the number of the exec...

Страница 19: ...d by the manufacturer is allowed The lifting and carrying should be made only with the both hands from below as the furnace stands on end No carrying and transportation in another state except for vertical position is allowed Furnace CERAMICMASTER E10 1 pc Vacuum pump PVD M22 1 pc Power cable 1 pc Flexible tube for the vacuum 1 pc Spare fuses 1 25А 250V 1 pc 8A 250V 2 pc User Manual PRODUCER VOP L...

Страница 20: ...ter E10 WARRANTY SHEET VOP Ltd warrants the consumer for proper operation of all parts and materials in this product during a period of 12 months since the day of its purchase During this period VOP Ltd or its authorized persons will repair on its own account all defects which have occur during the normal operation of the machine Defects caused by improper transportation storage and manipulation o...

Отзывы: