In the setting mode:

Enter one  set   number(3 digits)  from  000  to  999  data  storage  units,

yellow LED indicator will be flashing:

1.

press the button        twice to clean up;

2. If green LED indicator is on, means this number data storage unit can

be added card and passwords in.

Add card and passwords steps:

1. Enter in setting mode, and the yellow LED indicator will be flashing.
2. Input three-figure from 000 to 999 data storage units

.

3.

passwords(correlative for the card just added in this data storage unit).
The length of passwords should  be  the  same  as  admin  code.  For
example,  the  admin  code  is  12 (two is the  length),   herein  should
setting two digits passwords,  you can set 00-99  as your  passwords.

If the admin code is 123 (three is the length), herein should setting

three digits passwords, you can set 000-999 as your passwords. The
rest may be deduced by analogyˇˇ After  the  sound  "BI",   means
card added in and passwords setting successfully.

Press the button      to quit setting mode.

If red LED indicator is on, means there is data stored in this set of unit,

,   and the  green

LED indicator lighting
Swipe card, and a sound "BI" means added in. Then input the correlative

Add the user card and code ( ZONE 1 )

Set the length of passwords

In the setting mode:

Press  the button             and yellow LED indicator will be flashing, then

press the button            and a sound "BI" as reminder, then input X(X=2,3,4,
5,6):

2--Stands for the password/code digit length is 2(00-99)
3--Stands for the password/code digit length is 3(000-999)
The rest may be deduced by analogy, and the maximum is 6.

A sound "BI" as reminder, means digit length setting successfully. If  the

sound is "BI BI BI", means digit length is as same as the existence, and new

setting is not permitted.

Press the button      to quit setting mode.

4

NOTICE

Once the digit length changed, all added
cards and passwords will be cleared.

In the setting mode:

Press the button     and    , the mode indicator will flash yellow, follow

the button       twice, the  mode indicator will turn yellow,  a long beep will
be heard. It indicates that only the card access is available.

Press the button     and    , the mode indicator will flash yellow, follow

the button     and     , the mode indicator will turn yellow,  a long beep will
be heard, it indicates that both the card and code access are available.

Press the button      and      ,   the  mode  indicator  will  flash  yellow,

follow the button     and     , the mode indicator will turn yellow and a long
beep will be heard,  it indicates that card and code  access  combined  is
available.

Press the button      to quit the setting mode.

1.

2 relays can be programmed  for  opening the lock,  up  to

1000 user  cards  and correlative  codes can be stored into ZONE 1,  10

user cards or codes can be stored into ZONE 2 . In addition, ZONE 1
can be programmed for 3 modes to open the lock: card access(use card
only), card and code access(use  either  card  or  code),  and  combined
access(use card and code together). ZONE 2 could be programmed for
door bell.

2. Default code is 1234.
3. Input the admin default code twice (1234+1234). But

a. If the admin default code you set is two digits, please input 12 12
b. If the admin default code you set is three digits,

ZONE 1 and

please input 123 123

c. If the admin default code you  set is  five  digits, please input 12345

12345

The rest may be deduced by analogy...... The admin codes is max 6 digits.

After you enter in the setting mode, the yellow LED will be on.

.

Access mode setting

OPERATION

Содержание VHA30

Страница 1: ...Instruction Manual 16 1 VHA30 VHA30N ...

Страница 2: ...2 15 ...

Страница 3: ...re 3 lift the lower cover for less than 20 and remove the front cover gently 0 INSTALLATION Red power DC inputŁ 12V 24V Black power AC inputŁ V 24V Brown door status detecting Orange unlocking button 1 Yellow unlocking button 2 Green GND Blue NO 2 Purple COM 2 Gray NC 2 White NO 1 Pink COM 1 Aqua NC 1 Shielded ground 12 Pay attention for right polar connection Door bell Shielded ground VHA30 Wirin...

Страница 4: ...hrough the large centre hole in back case and keep level 4 Connected accurately the system wiring following the label enclosed on the rear 5 Put the unit back and screw it on by using the spline tool INSTALLATION Black White 485 Shielded ground Red power DC input 12V 24V Black power AC input V 24V Brown door status detecting Orange unlocking button 1 Yellow unlocking button 2 Green GND Blue NO 2 P...

Страница 5: ...er means added in successfully Press the button to quit setting mode Modify the user code of ZONE 1 In relative passwords ress the button to quit setting mode the setting mode Press the button and the yellow LED indicator will be flashing then press the button and a sound BI as reminder Then input The length of should as same as admin code P three figure 000 to 999 data storage units and input cor...

Страница 6: ...s turned on Press the button to quit the setting mode NOTICE The relay in ZONE 2 for door bell is available if the function of door bell is turned on but the function or door lock is inactive Press the button in standby mode the relay contacts one time the door bell ringing is triggered Turn on off the door bell In the setting mode Press the button and the mode indicator will flash yellow follow t...

Страница 7: ...ing successfully If the sound is BI BI BI means digit length is as same as the existence and new setting is not permitted Press the button to quit setting mode 4 NOTICE Once the digit length changed all added cards and passwords will be cleared In the setting mode Press the button and the mode indicator will flash yellow follow the button twice the mode indicator will turn yellow a long beep will ...

Страница 8: ...ut password once to open the door swipe card or input password again to close the door Press the button to quit the setting mode In the setting mode Press the button and mode indicator will flash yellow follow the button twice a continuous beep will be heard and mode indicator will turn yellow it indicates all user cards and codes have been cleaned out successfully Press the button and mode indica...

Отзывы: