2. Technical Specifications
DCR 6024/6128/6000
2 – 8
Planning and Installation – Rev. 1 / 7. 2001
2.4
DATA SYSTEM
2.4.1
DATA INPUT / OUTPUT
HIPPI
Duplex, Hippi serial optical acc. to
following standards (or equiv.):
Hippi framing protocol specification
IEC 11518–2
Hippi serial specification
ANSI X3.300–1997
FIBRE OPTIC CABLE
Type
50/125 MMF
Length
500 m max.
TYPICAL DATA RATES
Net data rate
100 MBytes/sec.
Typical acheivable data rates:
Telecine
SPIRIT / SPECTER
approx. 60 MBytes/sec
TransferEngine on SGI platform
OCTANE
approx. 60 MBytes/sec
ONYX 2000
approx. 85 MBytes
A Transfer rate of approx 60 MBytes will lead to the following typical telecine speeds:
2k (2048 1556)
4 – 5 frames / sec
HDTV (1920 x 1080)
8 frames / sec
Note:
The net data rate is specified in the Hippi standard with 100 MBytes and includes hand-
shake signals which will use some percents of transfer traffic and decreases the net data
rate by this amount. The typical data transfer rate depends on the performance of the
workstation and may vary depending on actual configuration.
2.4.2
DPX MONITORING
SIGNAL
XGA–2 standard
R,G,B, HD, VD
Resolution
1024x768
Frame rate
80 Hz
Supported DPX modes
3 x 8 bit RGBK
3 x 10 bit RGB
3 x 10 bit exp. to 16 bit
2 x 16 bit Y only
3 x 10 bit Y only
DPX resolutions
256 x 256 to
2048 x 1556 Pixels
2.4.3
CONTROL
Control System
protocol
iMCS
IEEE 802.3
Содержание DCR 6000
Страница 1: ...DCR 6024 6128 6000 MEDIA RECORDER Bild im Format 16 9 Planning Installation Manual...
Страница 9: ...Safety Instructions DCR 6024 6128 6000 IV Planning Installation Rev 1 7 2001...
Страница 17: ...1 General DCR 6024 6128 6000 1 8 Planning and Installation Rev 1 7 2001...
Страница 21: ...1 General DCR 6024 6128 6000 1 12 Planning and Installation Rev 1 7 2001...
Страница 41: ...1 General DCR 6024 6128 6000 1 32 Planning and Installation Rev 1 7 2001...
Страница 53: ...2 Technical Specifications DCR 6024 6128 6000 2 12 Planning and Installation Rev 1 7 2001...
Страница 83: ...4 Connections DCR 6024 6128 6000 4 6 Planning and Installation Rev 1 7 2001...
Страница 95: ...4 Connections DCR 6024 6128 6000 4 18 Planning and Installation Rev 1 7 2001...
Страница 105: ...4 Connections DCR 6024 6128 6000 4 28 Planning and Installation Rev 1 7 2001...
Страница 136: ...6 Interfaces DCR 6024 6128 6000 6 17 Planning and Installation Rev 1 7 2001 A and B are defined as shown below...
Страница 137: ...6 Interfaces DCR 6024 6128 6000 6 18 Planning and Installation Rev 1 7 2001...
Страница 142: ...7 DTV Applications DCR 6024 6128 6000 7 5 Planning and Installation Rev 1 7 2001 7 5 PARAMETER SHEET more in preparation...
Страница 143: ...7 DTV Applications DCR 6024 6128 6000 7 6 Planning and Installation Rev 1 7 2001...
Страница 148: ...9 Index DCR 6024 6128 6000 9 3 Planning and Installation Rev 1 7 2001...
Страница 149: ...9 Index DCR 6024 6128 6000 9 4 Planning and Installation Rev 1 7 2001...