EN
8
WWW.VONROC.COM
control the room temperature so do not use this
heater in spaces when they are occupied by per-
sons not capable of leaving the room on their own,
unless constant supervision is provided. The device
is to be used only for its prescribed purpose. Any
other use is deemed to be a case of misuse.
TECHNICAL SPECIFICATIONS
Model No.
PH502ACPH503AC
Voltage
220–240 V ~
Frequency
50-60 Hz
Power
2000W
Power settings
1: 1000W
2: 2000W
Heating element type
Low glare lamp
Heating time
1 second
Wave length
0.78-1.4 microns
Radiant efficiency
90%
Heating distance
4-5m
Heating area
10-12m²
Colour temperature
1500K
Overheat protection
Yes
Electronic soft start
Yes
Ingress protection class
IP55
Protection class
Class I
Weight
2.03 kg
DESCRIPTION
The numbers in the text refer to the diagrams on
page 2-5.
1. Heater
2. Protective grill
3. Receiver for remote control
4. Power cable
5. On/off switch
6. Mode button
7. Remote control on/off switch
8. Power level 1 button
9. Power level 2 button
10. Mounting bracket
11. Sleeve anchor
12. Screw with washers
13. Nut
14. Bolt
3. ASSEMBLY
This heater should be installed by a
competent person, i.e. a qualified electrician.
Always disconnected the heater from the
electrical supply and allow it to cool before
installation.
Installing the heater (Fig. AN)
Always mount the device with the supplied
accessories.
Before starting the installation, take the following
into consideration:
• Place the device on a firm, level surface.
• The device must be mounted so that there is
50 cm of free space between the heater and
any ceiling, tent canvas etc. There must also
be at least 1.80 m between the ground and the
underside of the device. Refer to Fig. J and K.
The device may never be hung at an angle!
• Ensure that the power supply cable is well
mounted and that it does not come into contact
with reflector of the heater or that does not trail
into heated area.
• Do not install the heater on an inflammable
surface.
• If the heater is to be used outside, a weather-
proof outlet is highly recommended.
• Before drilling ensure that there are no wires or
water pipes in the area where the heater is to
be installed.
To install the heater on a wall or ceiling, follow
these steps:
1. The device is supplied with the mounting acces-
sories as shown in figure C.
2. Drill a total of 4 holes using the dimensions in
figure D. The hole diameter should be the same
diameter as the anchor diameter: 8mm. Drill at
least 10 to 15 mm deeper than the expected
embedment. Ensure the holes are level and at
exactly the same height.
3. Clean out the holes of any debris.
4. Set the nut flush with the top of the sleeve
anchor (11), shown as step 1 in figure E.
5. Insert the sleeve anchor (11) into the hole in
the base material, shown as step 2 in figure E.
Using a hammer, insert the sleeve anchor as far
until the washer and nut are tight against the
Содержание PH502AC
Страница 2: ...2 WWW VONROC COM A B C 3 1 2 14 13 12 11 10 5 4 7 8 6 9...
Страница 3: ...3 WWW VONROC COM D E F G 12 12 10 10 10 11 10 11...
Страница 4: ...4 WWW VONROC COM J H K I L 14 13...
Страница 5: ...5 WWW VONROC COM M N...
Страница 68: ...2021 VONROC WWW VONROC COM 2104 19...