background image

A5P | 01

Item

Symbol

Value

Unit

Item

Unit

Heat Output

Type of heat input for Electrical Storage Heaters 

only (select one)

Nominal Heat
Output

Minimum Heat

Output (indicative)

Maximum 

Continious Heat

Output

Manual heat charge control with 
integrated thermostat. 

Manual heat charge control with room 
and/or outdoor temperature feedback.

Electronic heat charge control with 
room and/or outdoor temperature 
feedback

no

2.5

1.2

2.5

N/A

N/A

0.00025

no

no

no

no

no

no

yes

yes

no

no

no

no

no

no

no

Auxiliary electricity consumption

Fan assisted heat output

At nominal

heat output

At minimum

heat output

In standy mode

Model

Type of heat output/room temperature control

(select one)

2500645

Single stage heat output and no room
temperature control

Two or more manual stages, no room
temperature control

With mechanical thermostat room 
temperature control

With electronic room temperature 
control

Electronic room temperature control
plus day timer

Electronic room temperature control
plus week timer

Other control options (multiple selections possible)

room temperature control with 
prescence detection

room temperature control with 
open window detection

with distance control option

with adaptive start control

with working time limitation

with black bulb sensor

Contact Details

P

nom

P

min

P

max

EL

max

EL

min

EL

SB

kW

kW

kW

kW

kW

kW

DOMU Brands Ltd, 5th  & 6th Floor, The Tower, Deva City Office Park, Salford, M3 7BF

INFORMATION REQUIRMENTS FOR ELECTRICAL LOCAL SPACE HEATER

Содержание 2500645

Страница 1: ...switch The thermal cut out will activate and shut down the appliance should the appliance overheat Unplug from the mains and or battery and allow to cool for 30 minutes before re use CAUTION Do not i...

Страница 2: ...a Residual Current Device RCD UK EU Ground Fault Indicator US Do not use with a damaged cable or plug If the supply cable is damaged it must be replaced by a qualified engineer or authorised service...

Страница 3: ...or move the appliance whilst in use Do not operate continuously for periods longer than those marked on the product or indicated in the instructions Ensure the appliance is switched off and unplugged...

Страница 4: ...output room temperature control select one 2500645 Single stage heat output and no room temperature control Two or more manual stages no room temperature control With mechanical thermostat room temper...

Страница 5: ...A5P 01 SPECIFICATION 1 Radiator Fins 2 Adjustable Thermostat 3 Power Switch 4 Front handle 5 Timer 6 Cable Holder 7 Wheel Base 8 Wheels 1 7 8 2 3 4 5 6...

Страница 6: ...the paint finish or your floor surfacing see Fig 1 2 Fit the wheels assemblies onto the radiator by placing the U shaped bolts between the outermost fins on each side of the radiator see Fig 2 4 3 Se...

Страница 7: ...I Both switches down with both indicators illuminated A CLOCK 24 HOUR B LIVE TIME ARROW C TIMER SWITCH D SEGMENTS A B C D 4 Turn the Thermostat Dial clockwise to the III position When the room tempera...

Страница 8: ...d OFF NOTE To set the heater to turn on at 8pm and turn off at 9pm push 4 segments between 20 and 21 outwards Fig 1 3 Move the timer switch to symbol to enable the timer Fig 2 4 If the timer switch is...

Страница 9: ...unplug the appliance and allow to cool fully for approximately 30 minutes Follow the operation instructions to restart the appliance after removing the source of the overheating poor ventilation item...

Страница 10: ...wed accurately Any abuse of the product or the manner in which it is used will invalidate the warranty Returned goods will not be accepted unless re packaged in its original packaging and accompanied...

Отзывы: