background image

7

Remove existing exit device

and old strike from door.

Exit device

Match  master  cam  function

for new XP device to that of

removed  exit  device.

4

NL drive

screw

A.

Inspect underside of old center case for master cam.

B.

If NL drive screw (shown below) has been removed, it

must be removed from new XP center case as well.

If NL drive screw is present in old center case, leave

NL drive screw in new XP center case.

Lock

slide

Master

cam

RETROFIT INSTALLATION

2

Install new 909 strike to

replace  299/299F  strike.

A.

Re-drill and tap existing center strike hole for 1/4”-20.

B.

Attach strike to frame with new center screw and

locking plate and position strike against door.

C.

Mark and prepare 2 outer holes for 1/4”-20 and

install screws.

Existing center

strike hole

Locking

plate

1

3

Mark  and  prepare  2  new

support holes in door.

A.

Align plastic template with existing holes as shown.

B.

Mark 2 new holes as shown.

C.

Prepare 2 new holes per chart below:

#25 Drill

#10-24 tap

Met

al

W

oo

d

1/8” Drill

pilot 1” deep

2 new holes

Plastic template

Go to page 5-6 and continue

device installation steps 7-10.

909 strike

*See page 11 for 954 installation

NOTE:

If plastic template will not align correctly with the 4 outer holes,

bolt new XP exit device on door temporarily with the 4 screws

and use it as a template to mark the 2 holes shown above.

Old 299/299F or 499F strike cannot be used

with XP98/99 device. Strike must be

removed and replaced with new strike.

Old strike Replace with

299/299F

909

499F

954*

CAUTION

!

Содержание CDXP98

Страница 1: ...Screw chart 2 Preparation chart 3 Device installation 4 6 Retrofit installation 7 Hex dogging information 8 CD cylinder dogging 9 Cut device 10 954 strike installation 10 Special tools needed Taps 10 24 1 4 20 Drill bits 7 25 1 8 1 4 5 16 3 8 13 32 Please give these instructions to building owner after device is installed Rim Exit Device XP98 XP99 Installation Instructions ...

Страница 2: ...ew G 8 18X3 8 Threadcutting 4qty Metalframe 1 4 20X3 4 3 qty F D 10 16X3 8 Threadcutting 2 qty Endcapscrew E 10 24X1 4 qty 10 24X1 1 2 4 qty 10 X 1 1 4 Wood screw 4 qty Surface mountor Sexbolts 2 1 4 door Surfacemount wood Sexbolts 1 3 4 door C 10 24X1 3 8 4 qty 10 24 X 1 7 8 4 qty 990Trims 1 3 4 door 990Trims 2 1 4 door Packaged with trim SCREW CHART B Metalframe 1 4 20X3 4 6 qty Woodframe 14X1 1...

Страница 3: ... Sex bolts 25 Drill 10 24 tap 1 8 Drill pilot 1 deep 1 4 Drill device side 13 32 Drill trim side 13 32 Drill thru Metal Wood Metal Wood End cap bracket 2 holes Prepare holes after center case is mounted and device is leveled PREPARATION CHART RHRshown LHR opposite Go to Device Installation on next page before using this preparation chart C L C L X X Outside cylinder applications Mark with template...

Страница 4: ...page 10 Strike Body against door A See Screw Chart on page 2 for screw type and size C L 7 Drill 1 4 20 tap 2 places Metal DEVICE INSTALLATION Strike Body against door Note For retrofit applications where an existing 98 99 Rim device is being replaced see Retrofit Installation on page 7 Position template against strike and on and mark door 909 strike shown 954 strike also works with this template ...

Страница 5: ... sizes D E C IMPORTANT Two support screws MUST be installed With NL drive screw removed key locks and unlocks lever knob or thumb piece For trims listed below REMOVE NL drive screw 996L 696TP 990TP 996K 697TP With NL drive screw installed key retracts latch bolt DO NOT remove NL drive screw for the following applications NL EO DT trims and 98 99 2 double cylinder devices i e TP 2 L 2 and K 2 If tr...

Страница 6: ...perational check until device functions as described above Strike plate 7 Drill 1 4 20 tap Metal Locate hole at center of slot 7 Drill 1 4 20 tap 2 places 909 Strike 954 Strike A B 9 Verify gap between latch bolt and strike and adjust strike as needed Strike MUST have some gap Gap no more than 3 16 12 Note about the XP latch operation The XP latch bolt operates differently from a standard latch bo...

Страница 7: ...ion strike against door C Mark and prepare 2 outer holes for 1 4 20 and install screws Existing center strike hole Locking plate 1 3 Mark and prepare 2 new support holes in door A Align plastic template with existing holes as shown B Mark 2 new holes as shown C Prepare2newholesperchartbelow 25 Drill 10 24 tap Metal Wood 1 8 Drill pilot 1 deep 2 new holes Plastic template Go to page 5 6 and continu...

Страница 8: ...ace hex key in hole as shown and turn counterclockwise releasing pushbar To undog exit device Note Dogging is recommended during times of high traffic through door 1 Depress pushbar 2 Place hex key in hole as shown and turn clockwise Pushbar stays in down position To dog exit device Hex key CCW CW ...

Страница 9: ... mechanism case Std mortise cylinder Mortise cylinder cam Std mortise cylinder Mortise cylinder cam CD function conversion Figure 1 Figure 2 Std mortise cylinder Cylinder collar Dogging plate cover Offset toward pushbar Cylinder locating washer Cylinder lock nut Mechanism case 2 Turn cylinder key clockwise approx 1 8 turn for standard dogging Dogging procedure 1 Depress pushbar DO NOT USE ON FIRE ...

Страница 10: ...a being cut CUT DEVICE Cut device square and remove all burrs 1 1 2 minimum clearance with endcap removed Devicealigned with mounting holes 3 Cut device square NOTE Device must be cut square for proper end cap fit 4 Slide anti rattle clip into device Tape Cover plate flush to end of channel Pushbar Remove anti rattle clip 1 Measure amount to cut off device Anti rattle clip 2 Minimum If 5 8 diamete...

Страница 11: ...11 ...

Страница 12: ... Allegion 2016 Printed in U S A 911000 00 Rev 05 16 e Customer Service 1 877 671 7011 www allegion com us ...

Отзывы: