background image

© Allegion 2014

Printed in U.S.A.

941022-00 Rev. 01/14-c

Customer Service

1-877-671-7011 www.allegion.com/us

INSTALLATION INSTRUCTIONS

55 Rim Device

(for 22 and 98/99 Rim and Vertical Rod Devices,

see other side)

1.

Prepare inside face of door for exit device.

See exit device instructions for holes, line

X-X and center lines.

2.

Prepare outside face of door for cylinder.

A.

Transfer line X-X from exit device side of

door to cylinder side of door. Use extra

care if edge of  door is beveled. Be sure

line X-X is parallel to edge of door.

B.

Locate and prepare all holes as shown.

3.

Apply  cylinder.

A.

Cut cylinder tailpiece to proper length.

B.

Install cylinder and assemble component

parts (Figure 1).

4.

Apply cylinder mounting screw and tighten.

5.

Apply device.

A.

Remove key from cylinder.

B.

Attach lock stile case to door.

C.

Test key action.

LHR shown

RHR opposite

Figure 1

Standard rim cylinder

Cylinder base

Spacer collar

Cylinder disc

Cylinder screws

Cylinder thru bolt

Countersink washer

For cutouts on inside face of door, see exit device instructions

55 Rim Device (for 22 and 98/99 Rim and

Vertical Rod Devices, see other side) 

X

X

1/4”

5/8”

1/4”

1/2” dia.

Corresponds to

center line of exit

device on exit

device instructions

Wood Door

X

Line X-X corresponds to line X-X on exit device instructions

X

1-3/8”

dia.

1-9/16”

3/8”

1-3/8”

3/8”

1/2”

dia.

Metal Door

Outside face

of lock stile

Inside face

of lock stile

1-3/4”

exit device

exit device

CL

CL

C cylinder

L

C exit device

L