Group 30 Electrical System—VNL, VNM
Service Procedures
6
W3001007
1) Spacers
Install the fuse panel with 3 torx bolts.
Align the 2 plastic spacers with 2 bolts
through the spacers, taking care to
route the wires so that none are
caught between the spacers and
mounting brackets, or between the
spacers and fuse panel. Torque to
4.5 ± 0.5 Nm (40 ± 5 in-lb).
7
W3000794
Reach through the ashtray opening to
install the lower fuse panel bolt.
Torque to 4.5 ± 0.5 Nm (40 ± 5 in-lb).
8
Install the ashtray housing and ash-
tray. Torque ashtray mounting screws
to 0.4 ± 0.1 Nm (3.5 ± 1 in-lb).
9
Install the fuse panel cover and the
top TEC panel cover. Torque screws
to 2.5 ± 0.5 Nm (22 ± 5 in-lb).
10
Connect the battery cables, positive
side first. Torque nuts to 20.3–24.4
Nm (15–18 ft–lb).