![Volvo Penta V8-225 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/volvo-penta/v8-225/v8-225_operators-manual_1049013050.webp)
Draining Raw Water Side of Closed
Cooling System Engines
1 With the engine turned off:
Locate and open the blue drain plug on the each
exhaust elbow.
Do not drain the exhaust manifold or engine block.
NOTICE!
Be sure that all water is drained from the
elbows. If no water comes out of the drains, use a piece
of wire to clear any obstructions from the drain holes.
NOTICE!
When draining the starboard elbow, take
care to direct the drained water away from the starter
to prevent water damage to the starter.
2 After the water has completely drained, reinstall the
drain plugs and tighten securely.
3 Loosen the hose clamps and remove the hoses
from the raw water pump.
4 Loosen the heat exchanger anode and allow water
to drain. After water has stopped draining, reinstall
the anode. See
.
5 Reinstall all hoses and secure all clamps, in the
same orientation as removed.
P0013103
51534
P0018340
Engine Shutdown
48