Monitoring EVC information
Each engine (1, 2 and 3) has its own display.
NOTE!
Each EVC system display have three win-
dows. The two windows beside each other in the
upper section of the display (shows engine rpm and
coolant temp) are fixed and cannot be controlled by
the control panel.
The displays always start up in the MONITORING
MENU (A). The following buttons are used when
monitoring EVC information:
DISPLAY SELECTION BUTTON
When you want to shift information type in a display
you need to select that display using this button.
LED indication above the button:
Red/Yellow/
Green
Lit red:
Display1 is selected.
Lit yellow:
Display 2 is selected.
Lit green:
Display 3 is selected.
SELECTION WHEEL (X)
Turn this button to select which EVC information to
monitor.
NOTE!
The MONITORING MENU (A) contains mul-
tisensor data (optional), gauges and trip information
(optional).
Activating station
ACTIVATION BUTTON
Push this button on the control panel to activate a
station.
NOTE!
The control levers on all stations must be in
neutral position
LED indication above the button
: Red
Off:
The station is not active.
Lit:
The station is active.
Flashes:
The station can not be activated due to the
control levers not being in neutral on all stations or
that another station is active and locked.
Locking/unlocking station
Lock an active station by pushing the
ACTIVATION BUTTON.
Unlock an active station by pushing the
ACTIVATION BUTTON again
.
PADLOCK SIGN
LED indication:
Red
Off:
The station is unlocked.
Lit:
The station is locked and the boat can only be
operated from the activated station.
Changing station
To change station, make sure that the control le-
vers on all station are in neutral position. Unlock (if
locked) the station that you want to leave and acti-
vate the station you want to change to.
7747548
0
3
-2007
Activating docking station
NOTE!
Docking station can only be activated when
the engines are running.
Activating and locking/unlocking the docking station
is handled with the
ACTIVATION BUTTON on
the docking station panel, in accordance to instruc-
tions above.
A
X 1
3
2
1
2
3
1
2
3
1
2
3