75
Fault code register
2.9.9
O/R
Explanation: Internal fault in the EVC system.
Reaction
: Engine power is reduced.
Action
:
•
If the engine can not be operated from the chosen control panel, use an alternative control panel.
•
Please contact a Volvo Penta workshop
3.1.2
O
Explanation: Faulty control lever detection.
Reaction
: It is not possible to calibrate the control lever.
Action
:
•
Check that the control lever is connected.
•
Check that the lever combination is approved by Volvo Penta.
•
Please contact a Volvo Penta workshop if the fault remains.
3.1.3
O
Explanation: Too short lever movement between calibration points.
Reaction
: It is not possible to calibrate the control lever.
Action
:
•
Check that there is enough room, so that the control lever can reach the end points.
•
Check the mechanical connection to the potentiometer.
•
Switch the ignition off, and repeat the calibration procedure.
•
Check that the control levers are approved by Volvo Penta.
•
Please contact a Volvo Penta workshop if the fault remains.
3.1.4
O
Explanation: Incorrect lever calibration procedure.
Reaction
: It is not possible to calibrate the control levers.
Action
:
•
Switch the ignition off, and repeat the calibration procedure.
•
Check that the control levers are approved by Volvo Penta.
•
Please contact a Volvo Penta workshop if the fault remains.
3.1.6
O
Explanation: Control lever is not calibrated.
Reaction
: It is not possible to activate a control panel.
Action
:
•
Switch the ignition off, and repeat the calibration procedure.
•
Check that the control levers are approved by Volvo Penta.
•
Please contact a Volvo Penta workshop if the fault remains.