So that the paint is at the ideal viscosity, use the viscosimeter delivered with the turbine.
Dilute a part of the paint with the appropriate thinner.
Fill the viscosimeter to the top and let the liquid flow and monitor the time it takes until the trickle
of paint becomes discontinuous.
Check to see if the time corresponds to the indications in the table below:
- if the time is longer, increase the dilution
- if the time is shorter, add more paint
BUILDING PAINT
INDUSTRIAL PAINT
PRODUCTS
TIME
PRODUCTS
TIME
Oil paint
25 to 30 sec.
Hammered finish
30 to 50 sec.
Vinyl paint
30 to 35 sec.
Anti-rust
25 to 33 sec.
Acrylic paint
30 to 35 sec.
Lacquer, polyurethane
25 to 30 sec.
Pliolite
35 to 40 sec.
Lacquer, synthetic
22 to 27 sec.
Lacquer, brilliant, satin
25 to 27 sec.
Varnish, synthetic
20 to 22 sec.
Mat ceiling paint
25 to 30 sec.
Cellulosic
18 to 22 sec.
Anti-rust
25 to 33 sec.
Chromate and Wash-primer
18 to 22 sec.
Impression
20 to 25 sec.
Metallised
18 to 20 sec.