![Voltek 10-00474 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/voltek/10-00474/10-00474_owners-manual_1047622004.webp)
4
Wiring
10 DC Cable with Clips
—Connect the red clip to the positive terminal of the battery, and the black to the
negative.
1.
AC Outlets—
receptacles for
120V AC products with a total continuous power equal to the wattage (W) of
your inverter.
2.
Power Button—
Connect the inverter to the DC power and press down the button power switch, the AC
power is available.
3.
Port for Remote Control—
Connect the remote control switch and press down the switch, the remote control
function acts.
4.
USB Port
— Offer 5V power to USB equipment.
5.
Red LED Indicator—
When the inverter has shut down because of low or high input voltage, the red LED
indicator lights.
6.
Yellow LED Indicator —
When the power exceeds 1000W, the yellow LED indicator lights. When AC output
power exceeds 1200W+/-100W, the over current protection function will act.
7.
Green LED Indicator—
When there is DC power input, the green LED indicator lights.
8.
Positive DC terminal—
Connect the red end of the DC power cord to it.
9.
Negative DC terminal—
Connect the black end of the DC power cord to it.
10.
Cooling Fan and Ventilation Openings—
The high speed cooling fan protects the inverter from over-heating.
And the ventilation openings should be kept clear!
11.
Additional Protective Features
a)
Over Input Voltage Shut Off - When the 12 volt DC power supply voltage exceeds 15.5±0.5 volts, the
inverter will automatically shut down.
b)
Low Input Voltage Shut Off - When the 12 volt DC power supply voltage drops below 10.5±0.3volts, the
inverter will automatically shut down.
c)
Low Input Voltage Alarm - When the 12 volt DC power supply voltage drops below 11±0.3volts, an
audible alarm will sound.
d)
Over Heating Self-lock - When the internal temperature exceeds the regulated temperature due to the
increase of surrounding air temperature, the inverter will automatically shut down. When the internal
temperature drops below the surrounding air temperature, the inverter will automatically return to normal
operation.
4. Connecting and operating the inverter
When connecting the unit, please be sure to follow the guideline, cautions and warnings mentioned in this
manual. The inverter should be connected to your vehicle’s 12 V battery with DC clamp cables. No devices
should be plugged into the inverter until the inverter is properly connected and the inverter’s power indicator is
active.