Voltek 10-00474 Скачать руководство пользователя страница 10

10 

Maximum AC output 
power 

1000W 

1500W 

2000W 

3000W 

Maximum AC output 
surge power 

2000W 

3000W 

4000W 

6000W 

AC output frequency 
(nominal) 

59~61Hz 

59~61Hz 

59~61Hz 

59~61Hz 

AC output waveform 

modified sine 

wave 

modified sine 

wave 

modified sine 

wave 

modified sine 

wave 

DC output voltage 
range 

5V DC 

5V DC 

5V DC 

5V DC 

DC input voltage 
range 

12.8~13.2V 

DC 

12.8~13.2V 

DC 

12.8~13.2V 

DC 

12.8~13.2V 

DC 

Battery drain with no 
AC load 

0.6A (at a 
12V input) 

0. 6A (at a 
12V input) 

1 A (at a 
12V input) 

1 A (at a 
12V input) 

Low battery alarm 
trigger point 

11

.0.3

VDC  11

.0.3

VDC  11

.0.3

VDC  11

.0.3

VDC 

Low battery 
shutdown point 
(nominal)   

10.5 
0.3VDC 

10.5 
0.3VDC 

10.5 
0.3VDC 

10.5 
0.3VDC 

Low battery resume 
point (nominal)   

12.OV 

12.OV 

12.OV 

12.OV 

High battery 
shutdown point 
(nominal)   

15.5V 

15.5V 

15.5V 

15.5V 

fuse 

25A mini 
fuse X 5 

25A mini 

slip fuse

×

7

 

25A mini 

slip fuse

×

10

 

25A mini 

slip fuse

×

10

 

Efficiency(maximum)  85% 

85% 

85% 

85% 

 

c) Physical specifications 

Ambient operating temperature 

range 

32~104   

(0

~40

 

Содержание 10-00474

Страница 1: ...risk of injury please read this instruction manual and retain for future reference Should you have any questions or need any support please contact us at www voltec industries com Copyright 2009 VOLTE...

Страница 2: ...low Warning The inverter produces the same AC power as normal household outlets and thus has a shock hazard Please do not allow children to use the inverters unattended Be sure that there is at least...

Страница 3: ...will damage the inverter Failure to follow these safety guidelines may result in personal injury and or the damage to the unit It may also void the warranty 3 Features a LED Indicator Models 100W 300...

Страница 4: ...Ventilation Openings The high speed cooling fan protects the inverter from over heating And the ventilation openings should be kept clear 11 Additional Protective Features a Over Input Voltage Shut Of...

Страница 5: ...n the power inverter is not in use disconnect the DC cable clips from the battery to prevent unintended battery discharge Caution As the battery is used its voltage begins to fall When the inverter se...

Страница 6: ...D Player VCR 35 13 71 Electric Knife 85 5 65 PSP 16 30 00 Nintendo DS 12 40 00 Rechargeable Electric Knife 10 48 00 Household Battery Chargers 15 32 00 2 way Radios 10 48 00 5 LCD TV 10 48 00 BlackBer...

Страница 7: ...c Reference Chart PROBLEM CAUSE SOLUTION No power no indicator Battery is defective Replace battery Blown fuse Check and replace fuse Lose cable connections Check the connection to the battery Tighten...

Страница 8: ...rter s modified sine wave output requires true RMS voltmeter for accurate measurements Battery voltage is too low Recharge battery Battery run time is less than expected AC product power consumption i...

Страница 9: ...e 5V DC c DC Power Specifications Model 200W 400W 750W DC input voltage range 11 0 15 0V DC 11 0 15 0V DC 11 0 14 5V DC Battery drain with no AC load 0 35A at a 12V input 0 5A at a 12V input 0 5A at a...

Страница 10: ...2V DC Battery drain with no AC load 0 6A at a 12V input 0 6A at a 12V input 1 A at a 12V input 1 A at a 12V input Low battery alarm trigger point 11 0 3VDC 11 0 3VDC 11 0 3VDC 11 0 3VDC Low battery s...

Отзывы: