Connection

Be careful not to short-circuit the input and output lines. Keep the cables 

separate. If necessary, use the terminal strip supplied.
Switch off the power supply before making any connections, and secure 

against being unintentionally switched on again.

Connect the power meter as shown below before first use. 
Method a
1  Standard connection

2  Connection with external power supply (via enclosed micro-USB cable)

Method b

  When using method B, the positive output of the power meter is not connected!

3  Standard connection

4  Connection with external power supply

a)  Connecting inputs/outputs

1  Connect a power supply with a voltage of 5 - 60 V/DC to the input. Make sure that the 

polarity is correct when connecting the lines. The red line is positive (+), the black line is 

negative (-). 

  Connect the device only after you have carried out the pre-check.

2  Perform a pre-check before connecting the device. Switch on the mains voltage again 

and check whether the display is lit. If it is not lit, check whether the cables are connected 

using the wrong polarity.

3  During start-up, the firmware version is displayed on the display.
4  If necessary, delete the values which are stored in the memory by performing the steps 

described in „START-UP - b) Resetting measured values“.

5  Connect the device. Ensure you insert them in the correct polarity. The red line is positive 

(+), the black line is negative (-).

b)  (Optional connection of the external power supply)

If an external power supply (5 V/DC, not included in the delivery) is used, the measuring range 

extends from 5 - 60 V/DC to 0 - 60 V/DC. 
The external power supply is connected via a USB interface (see 7. Control elements, No. 6).

c)  More Information

1  Pay attention to the effective current direction. The energy source is on the left side and 

the loads - the energy sinks are on the right side. This is indicated by the arrows pointing 

towards the flow direction. Disconnect all the cables from any power sources before 

installing the device. 

2  Use at least the wire size (AWG 14 

 2,05 mm²) of the power meter lines for the 

electrical installation.

3  The use of rigid lines may lead to broken cables. Use flexible lines. 
4  If terminal strips (included in the delivery) are used, all (non-rigid) cables must have end 

splices. Check the crimped cable ends. All wires of a strand must be enclosed in the 

splice in order to ensure the total cable cross-section. The length of the wire end splice 

contact surface should be 6 - 7mm.

5  Undo the screws of the terminal strip and insert the wires until the insulation sits above 

the edge of the contact surface inside the terminal. Hold in position and tighten the 

screws. Insert the other strand into the opposite side as far as the edge of the contact 

surface and tighten the screw. If you cannot push the wire into the terminal strip far 

enough, check the length of the end splice.

6  After assembling, check and re-tighten all the screws. 

Start-up

a)  Switching the device on and off

1  Make sure that all cables are properly connected and not short-circuited. 
2  Turn the power on. 
3  During start-up, the firmware version and the factory default  

 

mode for data connection is displayed on the display. The power 

meter starts only when a power supply is connected.

b)  Setting the Recording Interval (Sampling Time)

The „Sampling Time“ screen appears when the start-up process is complete.
1  To get into the menu (Sampling Time) to adjust the recording  

(intervals, press and hold the RESET button during the start-up 

sequence for up to 5 seconds. The text „Sampling Time 180s“ is 

shown on the display.

2  You can preset the values for the recording interval in the range of 30 and 180 seconds. 

The various positions are adapted one after the other. Starting from the left, the hundreds 

come first. Then, tens and ones are entered.

3  To change the values press briefly the  

 

RESET- button.

4  To confirm the digit place press and hold the RESET button. The  

display shows „OK“. The value is now confirmed. After that you 

can enter the other places in the same way. 

5  Repeat steps 3 and 4 to do this.
6  After the last place of the „Sampling Time“ is confirmed, a letter  

appears in the upper right corner. „Y“ is“YES“, accept the set 

value, or „N“ which is „NO“ ’to discard the settings and assign a 

 

new value. Press briefly to switch between the points. 

7  The set time value is accepted by pressing and holding the  

RESET button when ‚Y‘ is selected. Now the display shows 

measured data. In case „N“ is the selected menu item, repeat 

these steps starting from point three.

MEASURING

1  Voltage (V): 

shows the current voltage in volts.

2  Current (A): 

shows the present current in amperes.

3  Power (W): 

shows the current power consumption in watts.

  The power measurement value is temporarily faded out to show the runtime when 

the display value changes within the cycle.

4  Cyclic change of the display value (scrolling display)

Содержание PM-60-A

Страница 1: ...stunden Wattstunden maximale Spannung maximaler Strom und maximale Leistungsaufnahme angezeigt 3 Pfeilrichtung Output Ausgang 4 Wechselnde Anzeige alle Messwerte werden nacheinander angezeigt 5 Eingang 6 Micro USB Buchse für externe Stromversorgung z B eine 5 V USB Power Bank 7 Ausgang 8 RESET Taste Zurücksetzen der Daten Bedienungsanleitung PM 60 A DC Leistungsmessgerät Best Nr 1499842 Bestimmung...

Страница 2: ...sen von der Hülse umschlossen sein um den gesamten Kabelquerschnitt zu gewährleisten Die Länge der Aderendhülsenkontaktfläche sollte 6 7mm betragen 5 Öffnen Sie die Schrauben der Lüsterklemmen und führen Sie die Drähte ein bis sich die Isolierung über der Kante der Kontaktfläche in der Klemme befindet Ziehen Sie die Schrauben in dieser Position fest an Führen Sie die zu kontaktierende Litze auf de...

Страница 3: ...ir Ihnen hier beschreiben wie Sie die mögliche Störung beheben können Das Aufzeichnungsintervall Sampling Time kann trotz Halten des RESET Knopfes nicht ein gestellt werden Die Einstellung der Sampling Time kann nur direkt nach dem Einschalten des Leistungsmess geräts erfolgen Sobald auf dem LCD Display Sampling Time erscheint drücken Sie 5 Sekun den lang die RESET Taste Anschließend sind Sie im S...

Страница 4: ...ro USB port for external power supply for example 5 V USB power bank 7 Output 8 RESET button data reset Operating instructions PM 60 A DC Power meter Item no 1499842 Intended Use The product is used to measure DC voltage It is possible to record currents voltages and the power consumption in watts of an electrical load Currents between 0 A and 20 A are measured continuously Currents of 30 A are re...

Страница 5: ...in the splice in order to ensure the total cable cross section The length of the wire end splice contact surface should be 6 7mm 5 Undo the screws of the terminal strip and insert the wires until the insulation sits above the edge of the contact surface inside the terminal Hold in position and tighten the screws Insert the other strand into the opposite side as far as the edge of the contact surfa...

Страница 6: ...ite holding down the RESET button the recording interval sampling time cannot be set The sampling time can only be set straight after switching on the power meter Once Sampling Time appears on the LCD screen press the RESET button for 5 seconds Now you are in the Sampling Time menu If Sampling Time is not shown on the display press the RESET button for 5 seconds as soon as Version No USB is shown ...

Отзывы: