38
13. DECLARATION OF CONFORMITY (DOC)
The manufacturer hereby declares that this product complies with the
essential requirements and regulations and all other relevant provisions of
the 1999/5/EC directive.
The Declaration of Conformity for this product can be found at
www.conrad.com.
14. TECHNICAL DATA
Operating voltage ..........................230 V/AC, 50 Hz (D/FR/CH)
220 – 240 V/AC, 50 Hz (UK)
Own power consumption ...............switched off <1.5 W
switched on <2.0 W
Max. power/current ........................resistive load:
3680 W / 16 A (D/FR)
3120 W / 13 A (UK)
2300 W / 10 A (CH)
inductive load:
1150 W (230 V/AC, 5 A)
Voltage measuring range ...............190 – 265 V /
±
1 % of the current value
Frequency measuring range ..........46 – 65 Hz
Current resolution ..........................0.001 A (16.00 A)
Power measuring range ................0.23 – 3680 W
Effciency factor measuring range ...0.01 – 1.00
Performance factor resolution .......0.01
GHG/CO
2
measuring range............0.001 - 39999.9 kg
GHG/CO
2
resolution ......................0.001 kg
Overload limit setting range ...........1 - 3699 W