Legal notice
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2014 by Conrad Electronic SE.
G
9. DISpOSAL
Electronic products are raw material and do not belong in the household waste. When the de-
vice has reached the end of its service life, please dispose of it, according to the current statu-
tory requirements, at your local collection site. Disposal in the household waste is prohibited.
10. TECHNICAL DATA / SpECIFICATIONS
The detailed data can be found in the help file (Help) in the measurement program.
General information
Digital storage oscilloscope (DSO)
Measurement inputs
Four separated channels CH1 - CH4
Bandwidth (-3 dB)
70 MHz
Feed impedance
1 MOhm // 25 pF
Max. input voltage
CH1 - CH4: 40 V/DC or 40 Vp/AC
External trigger: +/-20 V
Input connection
DC-AC-GND
Test probe ratio
1:1, 10:1, 100:1, 1000:1, 10000:1 and more
Vertical resolution
8-bit
Vertical precision
± 3%
Vertical deflection
10 mV - 5 V/div
Time scale
5 ns - 1000 s/div
Time scale precision
+/- 50 ppm
Ramp-up time
5 ns
Sampling rate
200 MS/s
Storage capacity max.
10 kpts - 16 Mpts/CH
Trigger mode
Auto, norm, single
Display mode
Y-t, X-Y (CH1-CH2)
Software
Windows
®
XP/VISTA/7/8 or later
Interface
USB2.0
Power supply mains adapter
100 - 240 V/AC 50/60 Hz max. 0.5 A
Output: 12 V/DC 1500 mA,
DC plug size: 5,5 x 2,1 mm, positive pole inner
Power supply DSO
8 - 36 V/DC, max. 1 A
Operating temperature
0 °C to +40 °C,
rel. humidity < 60%, non-condensing
Weight
approx. 1 kg (without accessories)
Dimensions (LxWxH)
approx. 255 x 45 x 190 mm
General information
Arbitrary DDS function generator
Frequency range
DC - 25 MHz
Frequency resolution
0.1%
Signal depth
4000 samples
Vertical resolution
12-bit
Frequency stability
<30 ppm
Amplitude
max. +/- 3.5 V
Output impedance
50 Ohm
Harmonic distortion
-50 dBc (1 kHz), -40 dBc (10 kHz)
4. DESCRIpTION OF THE pARTS
1 Earth connection and calibration output 1kHz/2 Vp-p square wave signal
2 BNC oscilloscope input Channel 4
3 BNC oscilloscope input Channel 3
4 BNC oscilloscope input Channel 2
5 BNC oscilloscope input Channel 1
6 Status LED displays
7 Opening for ventilation
8 BNC output function generator
9 BNC external trigger input
10 LAN area - Not available -
11 USB connection Type B
12 Power supply socket, DC input (polarity: inside positive pole)
5. INSTALLING THE MEASUREMENT pROGRAM
Before you connect the DSO to a computer, install the measurement program.
Switch on the computer and start the operating system.
Insert the enclosed software CD into the CD drive and close it. The automatic start mode will automatically
start the installation of the measurement program.
If this does not happen automatically, start the program “setup.exe” by double-clicking on the drive holding
the CD-ROM in the Explorer of your operating system. The software installation will start.
Please follow the on-screen instructions.
In the start menu’s program manager, a new folder called “DSO-XXXX” is created.
Leave the CD in the drive, for device installation.
6. CONNECTION AND INSTALLATION OF THE DSO
Plug the round DC plug of the mains adapter into the power supply jack (12) on the back of the DSO and
connect the mains adapter to a mains socket. The status LEDs (6) will light up.
Connect the provided USB connection cable with a free USB port at your computer and then with the USB
connection (11) at the DSO.
The operating system recognises the new hardware and starts the “Hardware Wizard”.
Follow the on the screen instructions.
Choose the installation option “Install software automatically (recommended)” and press “Continue”.
The system searches for the compatible driver. Follow the instructions on screen until, you are asked to
restart the operating system. Restart the computer, to update the new installation.
7. STARTING THE MEASUREMENT pROGRAM
Start the computer and connect the USB connector from the computer to the DSO, before starting the
program. Open the start menu, or the “DSO-XXXX” program on the desktop screen, by double-clicking on
the icon.
The measurement program’s start screen appears and initialises the DSO. Select your model, if necessary.
The DSO is ready for use.
Connect the test probe for the measurement input at the input for CH1 to CH4 (2 - 5). The generator output
occurs at the BNC output “OUTPUT” (8).
All parameters for the DSO are set automatically using the program key “AUTO” (Autoset), so
that the optimum signal display appears on the screen.
8. CLEANING
Always observe the following safety instructions before cleaning the device:
Live components may be exposed if the covers are opened or parts are removed, unless
this can be done without tools.
prior to cleaning or repairing of the device, all cables have to be detached and the device
has to be turned off.
Do not use any scouring cleansers, petrol, alcohol or the like to clean the product. These might attack the
surface of the device. Furthermore, the fumes are hazardous to your health and are explosive. Moreover,
you should not use sharp-edged tools, screwdrivers or metal brushes or similar implements for cleaning.
For cleaning the device or the display and the measuring cables, use a clean, slightly damp, fuzz-free,
antistatic cloth.
If you have technical questions concerning the use of the device, feel free to contact our
technical support.