background image

        

Legal notice

These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
 All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 
 These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved. 

© Copyright 2014 by Conrad Electronic SE.

G

9. DISpOSAL

   Electronic products are raw material and do not belong in the household waste. When the de-

vice has reached the end of its service life, please dispose of it, according to the current statu-

tory requirements, at your local collection site. Disposal in the household waste is prohibited.

10. TECHNICAL DATA / SpECIFICATIONS

The detailed data can be found in the help file (Help) in the measurement program.

General information

Digital storage oscilloscope (DSO)

Measurement inputs

Four separated channels CH1 - CH4

Bandwidth (-3 dB)

70 MHz

Feed impedance

1 MOhm // 25 pF

Max. input voltage

CH1 - CH4: 40 V/DC or 40 Vp/AC
External trigger: +/-20 V

Input connection

DC-AC-GND

Test probe ratio

1:1, 10:1, 100:1, 1000:1, 10000:1 and more 

Vertical resolution

8-bit

Vertical precision

± 3%

Vertical deflection

10 mV - 5 V/div

Time scale

5 ns - 1000 s/div

Time scale precision

+/- 50 ppm

Ramp-up time

5 ns

Sampling rate

200 MS/s

Storage capacity max.

10 kpts - 16 Mpts/CH

Trigger mode

Auto, norm, single

Display mode

Y-t, X-Y (CH1-CH2)

Software

Windows

®

 XP/VISTA/7/8 or later

Interface

USB2.0

Power supply mains adapter

100 - 240 V/AC 50/60 Hz max. 0.5 A
Output: 12 V/DC 1500 mA, 
DC plug size: 5,5 x 2,1 mm, positive pole inner

Power supply DSO

8 - 36 V/DC, max. 1 A 

Operating temperature

0 °C to +40 °C,
rel. humidity < 60%, non-condensing

Weight

approx. 1 kg (without accessories)

Dimensions (LxWxH)

approx. 255 x 45 x 190 mm

General information

Arbitrary DDS function generator

Frequency range

DC - 25 MHz

Frequency resolution

0.1%

Signal depth

4000 samples

Vertical resolution

12-bit

Frequency stability

<30 ppm

Amplitude

max. +/- 3.5 V

Output impedance

50 Ohm

Harmonic distortion

-50 dBc (1 kHz), -40 dBc (10 kHz)

4. DESCRIpTION OF THE pARTS

1  Earth connection and calibration output 1kHz/2 Vp-p square wave signal
2  BNC oscilloscope input Channel 4
3  BNC oscilloscope input Channel 3
4  BNC oscilloscope input Channel 2
5  BNC oscilloscope input Channel 1
6  Status LED displays
7  Opening for ventilation
8  BNC output function generator
9  BNC external trigger input
10  LAN area - Not available -
11  USB connection Type B
12  Power supply socket, DC input (polarity: inside positive pole)

5. INSTALLING THE MEASUREMENT pROGRAM

Before you connect the DSO to a computer, install the measurement program.
Switch on the computer and start the operating system.
Insert the enclosed software CD into the CD drive and close it. The automatic start mode will automatically 

start the installation of the measurement program.
If this does not happen automatically, start the program “setup.exe” by double-clicking on the drive holding 

the CD-ROM in the Explorer of your operating system. The software installation will start.
Please follow the on-screen instructions.
In the start menu’s program manager, a new folder called “DSO-XXXX” is created.

 

Leave the CD in the drive, for device installation.

6. CONNECTION AND INSTALLATION OF THE DSO

Plug the round DC plug of the mains adapter into the power supply jack (12) on the back of the DSO and 

connect the mains adapter to a mains socket. The status LEDs (6) will light up. 
Connect the provided USB connection cable with a free USB port at your computer and then with the USB 

connection (11) at the DSO.
The operating system recognises the new hardware and starts the “Hardware Wizard”. 
Follow the on the screen instructions.
Choose the installation option “Install software automatically (recommended)” and press “Continue”.
The system searches for the compatible driver. Follow the instructions on screen until, you are asked to 

restart the operating system. Restart the computer, to update the new installation.

7. STARTING THE MEASUREMENT pROGRAM

Start the computer and connect the USB connector from the computer to the DSO, before starting the 

program. Open the start menu, or the “DSO-XXXX” program on the desktop screen, by double-clicking on 

the icon.
The measurement program’s start screen appears and initialises the DSO. Select your model, if necessary. 

The DSO is ready for use.
Connect the test probe for the measurement input at the input for CH1 to CH4 (2 - 5). The generator output 

occurs at the BNC output “OUTPUT” (8).

 

 All parameters for the DSO are set automatically using the program key “AUTO” (Autoset), so 

that the optimum signal display appears on the screen.

8. CLEANING

Always observe the following safety instructions before cleaning the device:

 

 Live components may be exposed if the covers are opened or parts are removed, unless 

this can be done without tools.

 

 prior to cleaning or repairing of the device, all cables have to be detached and the device 

has to be turned off.

Do not use any scouring cleansers, petrol, alcohol or the like to clean the product. These might attack the 

surface of the device. Furthermore, the fumes are hazardous to your health and are explosive. Moreover, 

you should not use sharp-edged tools, screwdrivers or metal brushes or similar implements for cleaning.
For cleaning the device or the display and the measuring cables, use a clean, slightly damp, fuzz-free, 

antistatic cloth.

 

 If you have technical questions concerning the use of the device, feel free to contact our 

technical support.

Содержание DSO-2047G

Страница 1: ... LIEFERUMFANG DSO 2074G Netzteil mit 4 Netzstecker Adaptern Euro GB US AU 4 Tastköpfe mit umschaltbarem Spannungsteiler 1 1 10 1 Messsoftware Mini CD mit ausführlicher Anleitung im Software Menüpunkt Help USB Anschlusskabel 1m BNC Messkabel 90 cm Tasche Kurzbedienungsanleitung D BEDIENUNGSANLEITUNG Oszilloskop und Funktions generator Vorsatz DSO 2074G Best Nr 1182107 1 BestimmungsgemäSSe Verwendun...

Страница 2: ... Computer ein und starten das Betriebssystem Legen Sie die beiliegende Software CD in das CD Laufwerk ein und schließen es Der Autostart Modus startet automatisch die Installation des Messsoftware Erfolgt dies nicht automatisch so führen Sie einfach manuell im Explorer Ihres Betriebssystems auf dem Laufwerk der eingelegten CD ROM das Programm setup exe mit Doppelklick aus Die Installation der Soft...

Страница 3: ...fied measurement voltage of 40 V DC or 40 Vp AC Use divider probes if neces sary The product may be used only in the measurement category range CAT I for signal voltages It also contains an arbitrary DDS function generator 1 channel with which freely generatable and direct digital signals DDS can be generated The frequency range extends from DC 25 MHz with a vertical resolution of 12 bits and a st...

Страница 4: ...fore you connect the DSO to a computer install the measurement program Switch on the computer and start the operating system Insert the enclosed software CD into the CD drive and close it The automatic start mode will automatically start the installation of the measurement program If this does not happen automatically start the program setup exe by double clicking on the drive holding the CD ROM i...

Страница 5: ...commande et la représentation sont assurées par le logiciel de mesure joint Il correspond à une véritable interface utilisateur d oscillographe Des fonctions complémentaires disponibles sont un analyseur de spectre FFT des fonc tions spéciales mathématiques et un curseur pour la mesure des signaux La largeur de bande est de 70 MHz et la vitesse d échantillonnage en temps réel est de 200 MS s milli...

Страница 6: ...t lancez le système d exploitation Insérez le CD du logiciel fourni dans le lecteur puis fermez le lecteur Le mode Autostart lance automati quement l installation du logiciel de mesure Si l installation ne se lance pas automatiquement exécutez la alors manuellement dans l explorateur de votre système d exploitation en double cliquant sur le programme setup exe présent dans le CD inséré dans le lec...

Страница 7: ...geleverde meetsoftware Deze voldoet aan een feitelijk oscilloscoop bedieningspaneel Tevens staan een spectrumanalysator FFT wiskundige gespecialiseerde functies en een cursor voor het meten van signalen ter beschikking De bandbreedte bedraagt 70 MHz en de real time samplingsnelheid 200 MS s mega samples seconde De gemeten signalen kunnen in verschillende indelingen worden opgeslagen en opgeroepen ...

Страница 8: ...are te installeren Schakel de pc in en start het besturingssysteem Plaats de meegeleverde software CD in het CD station en sluit het De Autostart modus start automatisch de installatie van de meetsoftware Als dit niet automatisch gebeurt dan gaat u met de Verkenner van uw bedrijfssysteem naar het station waar u de cd rom in heeft geplaatst en voert u het bestand setup exe uit met een dubbelklik De...

Отзывы: