the endoscope may only be used for inspection of dead systems. the camera
head is made of metal and can lead to short circuits. For safety reasons,
disconnect all system parts from the power supply before every inspection.
Switching the endoscope on and off
Hold the “On/Off” button down for ca. 2 seconds to switch the device on. After a short time, the
1.
image filmed by the camera appears on the screen.
Hold the “On/Off” button down for ca. 2 seconds to turn the device off.
2.
Camera lighting
So as to be able to use the endoscope even in absolutely dark areas, continuously dimmable
LED lighting is integrated in the camera head. The number on the screen, next to the sun symbol,
indicates the brightness level of the LED light.
Press the “-” button to reduce the brightness.
1.
Press the “+” button to increase the brightness.
2.
Set the lighting in such a way that the monitor image displayed is not overexposed or
3.
underexposed.
rotating the camera image
The camera image can be rotated and flipped. This facilitates monitoring the camera image in
awkward positions. To do so, proceed as follows:
Press the “MODE” button in normal camera operation. The camera image is flipped
1.
horizontally.
Press the “MODE” button once more. The camera image is shown rotated 180° on the monitor
2.
Press the “MODE” button once more. The camera image is flipped horizontally again.
3.
Press the “MODE” button once more. The camera image returns to normal.
4.
PaL/ntSC video output
The endoscope facilitates video display for recording and documenting via an integrated
PAL/NTSC video output. The video format is detected automatically.
Use the included AV cable in order to establish the connection to your replay or recording
1.
device.
Insert the jack plug in the socket on the handle of the endoscope.
2.
Connect the phono plug to the video input of your replay or recording device.
3.
Switch the replay device on and choose the video input.
4.
The camera image is displayed if the connection and the choice of video source are correct.
5.
mirror, magnet and hook attachment
The mirror, magnet and hook attachment can be placed on the camera head. Parts that have
been lost can thus be searched for and retrieved.
main menU SettingS
8.
Press and hold the “MODE” button to enter the main menu.
button
Function within the menu
MODE
Select the parameter to be modified.
•
Confirm the modification and return to the main menu.
•
- / + button
Navigate up and down in the main menu.
•
Change the parameter value in the parameter setting.
•
Language select
German and English can be selected as menu languages. In order to adapt the menu language
to your needs, proceed as follows:
With the “+“ / “-” button, select the “LANGUAGE” menu option and confirm the selection with
1.
the “MODE” button.
With the “+” / “-” button, select your preferred language and confirm your selection with the
2.
“MODE” button.
Brightness, contrast and definition setting
With the “+” / “-” button, select the “BRIGHTNESS”, “CONTRAST” or “DEFINITION” option
1.
in the main menu.
Confirm the selection with the “MODE” button.
2.
With the “+” / “-” button, adjust your desired value. Confirm with the “MODE” button.
3.
Colour temperature setting
With the “+” / “-” button, select the “COLOR” option in the main menu..
1.
Confirm the selection with the “MODE” button.
2.
With the “+” / “-” button, select the desired colour temperature, “WARM”, “COLD” and
3.
“STANDARD”. Noted that changing the preset colour temperature setting also changes the
brightness, contrast and definition settings.
Set default
With the “+” / “-” button, select the “DEFAULT” option in the main menu.
1.
Confirm with the “MODE” button. Then the brightness, contrast and definition are reset to
2.
the default value.
return to operation
With the “-” button, select the “EXIT” option in the main menu.
1.
Confirm with the “MODE” button. Then the endoscope returns to its normal operation mode.
2.
rePLaCe the gOOSeneCK Camera
9.
Unscrew the connection joint. Follow the direction of the arrow imprinted on the joint.
1.
Carefully unplug the gooseneck camera.
2.
Carefully plug another compatible gooseneck camera or extension tube into the socket. Be
3.
careful not to break the pins inside the plug of the gooseneck camera.
Screw back the connection joint to fasten the gooseneck camera.
4.
the total length of the gooseneck camera should not exceed 4 m.
DiSPOSaL
10.
general
In order to preserve, protect and improve the quality of environment, protect human
health and utilise natural resources prudently and rationally, the user should return
unserviceable product to relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately
and not as municipal waste.
batteries / rechargeable batteries
The user is legally obliged
(battery regulation)
to return used batteries and
rechargeable batteries.
Disposing used batteries in the household waste is
prohibited!
Batteries/ rechargeable batteries containing hazardous substances are
marked with the crossed-out wheeled bin. The symbol indicates that the product
is forbidden to be disposed via the domestic refuse. The chemical symbols for the
respective hazardous substances are
Cd
= Cadmium,
hg
= Mercury,
Pb
= Lead.
You can return used batteries/ rechargeable batteries free of charge to any collecting
point of your local authority, our stores or where batteries/ rechargeable batteries are
sold.
Consequently you comply with your legal obligations and contribute to environmental
protection!
teChniCaL Data
11.
general
Operating voltage:
3.7 V/DC, Lithium battery
Battery capacity:
2000 mAh
Current consumption:
480 mA (operating), 5 mA (standby)
Screen size:
7.62 cm (3”)
Screen resolution:
320 x 240 pixels
Video format:
NTSC / PAL
Camera lighting:
4 white LEDs
Min. bending radius:
63.5 mm
Gooseneck length:
1 m (39”)
Camera diameter:
17 mm (0.66”)
Sensor size:
6.35 mm (1/4”)
Resolution:
640 x 480 pixels
Video frame rate:
30 frames/second
Focus:
15 to 25 cm
Protection class:
IP67 (goose neck only)
Operating temperature:
0 to +50 ºC
Storage temperature:
-20 to +60 ºC
Operating humidity:
5 to 85 % RH
Storage humidity:
5 to 85 % RH
Suitable for:
1 m extension (BN : 123306)
3 m extension (BN : 123308)
6 mm camera (BN : 123309)
Dimensions(W x H x D):
240 x 100 x 160 mm
Weight:
596 g
adaptor
Input voltage:
100 - 240 V/AC, 50/60 Hz
Input current:
.2 A
Output voltage:
5 V
Output current:
1 A
OPerating inStrUCtiOnS
Version 07/10
bS-100 X enDOSCOPe
Option no. 12 33 04
intenDeD USe
1.
The endoscope is an optical inspection device. At the end of the waterproof Gooseneck is a mini
colour camera with integrated dimmable LED lighting. The camera image is displayed on the built-in
TFT monitor. A PAL/NTSC video output is available. The endoscope is a visual aid for optical fault
diagnostics and inspection of dead systems and equipment. By means of the flexible Gooseneck,
the colour camera at the tip of the device can also be brought into inaccessible positions. Four white
light-emitting diodes allow you to see even in absolutely dark areas The Gooseneck and camera
head are waterproof and suitable for use in watery liquids (no acids or lye). The handle and monitor
must not be exposed to or immersed in any liquid. The Gooseneck camera head is changeable.
The power supply is via a built-in rechargeable battery or a USB power adapter that operates at
100 - 240 V/AC, 50/60 Hz. Operation in potentially explosive areas or use with humans or animals
is not permitted.
This product fulfils European and national requirements related to electromagnetic
compatibility (EMC). CE conformity has been verified and the relevant statements and
documents have been deposited at the manufacturer.
Unauthorised conversion and/or modification of the device are inadmissible because of safety
and approval reasons (CE). Any usage other than described above is not permitted and can
damage the product and lead to associated risks such as short-circuit, fire, electric shock, etc.
Please read the operating instructions thoroughly and keep them for further reference.
COntent OF DeLiVery
2.
Endoscope
•
Carry box
•
USB cable
•
AV cable
•
Operating instructions
•
Attachment set: hook attachment, magnet
•
attachment, mirror attachment
USB Power adapter
•
3.7 V battery
•
SaFety inStrUCtiOnS
3.
We do not assume liability for resulting damages to property or personal injury
if the product has been abused in any way or damaged by improper use or
failure to observe these operating instructions. the warranty/ guarantee will
then expire!
the icon with exclamation mark indicates important information in the
operating instructions. Carefully read the whole operating instructions before
operating the device, otherwise there is risk of danger.
Persons / Product
When not in use, store the endoscope in the carrying case. Sensitive surfaces (furniture
•
polish, etc.) might cause chemical reactions with the housing.
Avoid strong mechanical strains or vibrations. Make sure you never go below the minimum
•
bending radius of 63.5 mm.
Keep the unit out of the reach of children. It is not a toy.
•
Do not leave packaging materials unattended. They could become a dangerous playthings
•
for children.
On industrial sites, the accident prevention regulations of the association of the industrial
•
workers’ society for electrical equipment and utilities must be followed.
Only immerse the camera head and gooseneck in liquids that are voltage free! The gooseneck
•
must not be immersed deeper then the imprint on the joint of the endoscope. Please pay
attention to the markings on the gooseneck.
If you have a reason to believe that the device can no longer be operated safely, disconnect it
•
immediately and secure it against being operated unintentionally. It can be assumed that safe
operation is no longer possible if:
the device is visibly damaged,
-
the device no longer works and
-
the unit was stored under unfavourable conditions for a long period of time or
-
it has been subjected to considerable stress in transit.
-
You should also heed the additional safety instructions in each chapter of the operating
•
instructions for the connected devices.
Never switch the device on immediately after it has been taken from a cold into a warm
•
environment. Condensation that forms might destroy your device. Allow the device to reach
room temperature before switching it on.
The product must not be exposed it to extreme temperatures, direct sunlight, intense vibration,
•
or dampness.
batteries
Leaking or damaged batteries might cause acid burns when in contact with skin, therefore use
•
suitable protective gloves to handle corrupted batteries.
Batteries must be kept out of reach of children. Do not leave the battery lying around, as there
•
is risk, that children or pets swallow it.
Batteries must not be dismantled, short-circuited or thrown into fire. Never recharge non-
•
rechargeable batteries. There is a risk of explosion!
miscellaneous
Repair works must only be carried out by a specialist/ specialist workshop.
•
If you have queries about handling the device, that are not answered in this operating
•
instruction, our technical support is available under the following address and telephone
number: Voltcraft
®
, 92242 Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 7
OPerating eLementS
4.
1
2
3
4
5
6
7 8
Display
1.
“-” button
2.
“Mode” button
3.
“+” button
4.
“On/Off “ button
5.
TV-out socket
6.
Reset pin hole
7.
Mini USB socket
8.
inStaLLatiOn
5.
Carefully plug a compatible gooseneck camera or extension cable into the socket. Be careful
1.
not to break the pins inside the plug of the gooseneck camera. If you are using an extension
cable, connect a camera to the end of the extension cable.
Tighten the connection joint to secure the gooseneck camera.
2.
Charging the battery
6.
the battery is located inside the handle of the endoscope. you should not
replace the battery with any other battery.
the battery should only be removed or replaced by a specialist / specialist
workshop.
remove the battery when the endoscope is not going to be used for a long
period of time. Observe the correct polarity when replacing the battery.
The battery status icon shows the remaining battery power in five levels.
means the battery is fully
charged (higher than 4.0 V). When using for the first time or if the battery level is lower than 3.3 V,
appears, meaning the battery has to be charged. To do so, proceed as follows:
Connect the USB cable to the power adapter.
1.
Connect the other end of the cable to the “Mini USB” socket.
2.
Connect the power adapter to a mains outlet.
3.
The endoscope is turned on automatically. A pop up will window appear to ask if you would
4.
like to enter the standby mode. Press “+” and “-” to select. Then press “MODE” to confirm.
In standby mode, the battery is being charged and the endoscope will consume a minimum
amount of energy.
If you select not to enter standby mode, the endoscope enters normal operating mode. The
battery status shows the , , ,
icon sequence indicating the battery is charging.
These operating instructions are published by Voltcraft®,
Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 7.
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the
capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also
in part, is prohibited.
The operating instructions reflect the current technical specifications at time of print.
We reserve the right to change the technical or physical specifications.
© Copyright 2010 by Voltcraft®.
v2_07/10_02-HL