background image

11

• Power supply units are not allowed for use on human beings or animals.

• Hazardous voltages will be produced when the outputs of several power supply

units are connected in series (> 35 V D.C.).

• Do not cover the ventilation slots of power supply units. Such devices are cooled

by convection in most cases.

• Do not operate unattended power supply units and loads connected to them. Take

measures apt to protect and secure the loads connected from the effects pro-
duced by the power supply units (e.g. excess voltages, failure of the power supply
unit) and the effects and hazards originating from the loads themselves (e.g. inad-
missibly high power input).

• Power supply units may produce voltages exceeding 50 V D.C. in a malfunction

case. Such voltages cause hazards, even if the specified output voltages of the
devices are lower.

• When working under a voltage only use tools which are explicitly allowed for the

purpose.

• The two-pole plug at the output of power supply units may not be modified or

rebuilt.

• Avoid installing bare metallic cables and contacts. Cover all bare points by suit-

able, difficultly inflammable insulating materials or take other measures, thus pro-
tecting such points from being directly contacted. Likewise, take measures apt to
protect the electrically conducting elements of the loads connected from being
directly contacted.

• If there is reason to believe that safe operation has become impossible put the

power supply unit out of operation and secure it against any unintended operation.
Safe operation must be presumed to be no longer possible, if

- the unit exhibits visible damage
- the unit does not operate any longer
- the unit was stored under unfavourable conditions for a long period of time or
- the unit was exposed to extraordinary stress caused by transport.

Содержание 51 16 08

Страница 1: ...Switched Mode Power Supply Unit SPS 1504 OPERATING INSTRUCTIONS Seite 9 14 Alimentation universelle SPS 1504 NOTICE D EMLPOI Seite 15 20 Universele schakelnetvoeding SPS GEBRUIKSAANWIJZING Seite 21 2...

Страница 2: ...es in technology and equipment reserved Copyright 2008 by Voltcraft Informations l gales dans nos modes d emploi Ce mode d emploi est une publication de la soci t Voltcraft Lindenweg 15 D 92242 Hirsch...

Страница 3: ...pters listed up in the table of contents indicating the respective page number on page 10 Le mode d emploi suivant correspond au produit ci dessus men tionn Il comporte des instructions importantes re...

Страница 4: ...b von Kleinspannungsverbrauchern mit einer Betriebsspan nung von 6 oder 7 5 oder 9 oder 12 oder 13 5 oder 15 VDC Die Stromaufnahme eines angeschlossenen Verbrauchers darf bis 12 VDC 4 2 A und von 13 5...

Страница 5: ...weisung enthalten sind Das Ger t ist in Schutzklasse II aufgebaut Es ist darauf zu achten da die Isolierung weder besch digt noch zerst rt wird Das Netzger t darf nicht als direkte Ladeeinrichtung ver...

Страница 6: ...geben von welchen Gefahren ausgehen auch dann wenn die angegebenen Ausgangs spannungen der Ger te niedriger liegen Bei Arbeiten unter Spannung darf nur daf r ausdr cklich zugelassenes Werkzeug verwend...

Страница 7: ...de Spannungsmar kierung zeigt B Verbraucheranschlu Achten Sie beim Anschlu eines Verbrauchers darauf da dieser uneingeschaltet mit dem Netzger t verbunden wird Die Ausgangsspannung ist einstellbar von...

Страница 8: ...emmen f hren welche wiederum die Anschlu buchsen bzw die angeschlossenen Leitungen und oder deren Klemmen besch digen k nnen Wenn der Steckernetzadapter nicht ben tigt wird trennen Sie ihn vom Netz C...

Страница 9: ...50 60 Hz Leistungsaufnahme max ca 68 VA Ausgangsspannungen min 6 VDC bis max 15 VDC in 6 Stufen Ausgangsstrom max 4 2 A Leistungsabgabe max 50 Watt Abmessungen L x B x H 136 x 70 x 38 mm ohne Netzstec...

Страница 10: ...perating voltage of 6 or 7 5 or 9 or 12 or 13 5 or 15 V D C The power input of a device con nected may not exceed 4 2 A if up to 12 V D C are used and 3 2 A if from 13 5 to 15 V D C are used Any incre...

Страница 11: ...fety class II Take care not to damage or destroy its insulation Never use the power supply unit as a charging device proper Power supply units and their accessories are no toys and therefore should al...

Страница 12: ...ages of the devices are lower When working under a voltage only use tools which are explicitly allowed for the purpose The two pole plug at the output of power supply units may not be modified or rebu...

Страница 13: ...ints accurately to the respective voltage marking B How to connect loads When connecting a load make sure it is switched off before joining it to the power supply unit The output voltage is adjustable...

Страница 14: ...nals This in turn can damage the supply jacks or the cables connected and or their terminals If you do not need the plug in mains adapter disconnect it from the mains C How to do maintenance The power...

Страница 15: ...A C Mains frequency 50 60 Hz Power input max abt 68 VA Output voltages from min 6 V D C to max 15 V D C in 6 steps Output current max 4 2 A Power output max 50 watts Dimensions L x W x H 136 x 70 x 38...

Страница 16: ...mise en service de petits appareils fonctionnant sur 6 ou 7 5 ou 9 ou 12 ou 13 5 ou 15 VDC La consommation en courant de l appareil connect ne doit pas d passer 12 VDC 4 2 A et de 13 5 15 VDC 3 2 A Un...

Страница 17: ...e protection II Prenez soin ce que l isolation ne soit ni endommag e ni d truite L alimentation ne peut pas tre utilis e comme chargeur direct Les alimentations et accessoires ne sont pas des jouets e...

Страница 18: ...gendre une tension continue de 50V qui s av rerait dangereuse et cela m me si la tension de sortie indiqu e tait normalement moins lev e Les travaux sous tension ne doivent tre effectu s qu avec des o...

Страница 19: ...la fl che indique exactement le marquage de tension correspondant B Connexion d un r cepteur Veillez lors de la connexion d un r cepteur l alimentation ce que celui ci soit teint La tension de sortie...

Страница 20: ...ourrait conduire un endommagement ou m me la destruction des fils de branchement et ou des bornes Quand l adaptateur secteur n est pas utilis d branchez le du secteur C Entretien A part le nettoyage o...

Страница 21: ...ur 50 60 Hz Puissance absorb e env 68 mA maxi Tensions de sortie min 6 VDC jusqu max 15 VDC sur 6 chelons Intensit de sortie max 4 2 A Puissance utile max 50 Watt Dimensions Long x Larg x Haut 136 x 7...

Страница 22: ...aratuur met lage spanning met een bedrijfsspanning van 6 of 7 5 of 9 of 12 of 13 5 of 15 VDC Het stroomverbruik van een aangesloten verbruiker mag tot 12 VDC 4 2 A en van 13 5 tot 15 VDC 3 2 A stroomv...

Страница 23: ...gsteksten in deze gebruiksaanwijzing opvolgen Het apparaat vol doet aan veiligheidsklasse II Let er bovendien op dat de isolatie niet wordt beschadigd of verwijderd Het apparaat mag niet als direct op...

Страница 24: ...n meer dan 50 V gelijkspanning afgeven die gevaarlijk zijn ook wanneer de aangegeven uitgangs spanningen van de apparaten lager liggen Bij werkzaamheden onder spanning mag uitsluitend gereedschap word...

Страница 25: ...B Verbruikeraansluiting Zorg er bij de aansluiting van een verbruiker voor dat deze altijd uitgeschakeld met de netvoeding wordt verbonden De uitgangsspanning is instelbaar van 6 VDC DC gelijkspanning...

Страница 26: ...ie op hun beurt de aansluitbussen resp de aangesloten kabels en of de bijbehorende klemmen kunnen beschadigen Als de netvoeding niet wordt gebruikt koppelt u deze van het lichtnet los C Onderhoud Afge...

Страница 27: ...VAC 100 tot 240 VAC Netfrequentie 50 60 Hz Opgenomen vermogen max ca 68 mA Uitgangsspanningen min 6 VDC tot max 15 VDC in 6 trappen Uitgangsstroom max 4 2 A Opbrengst max 50 Watt Afmetingen lxbxh 136...

Страница 28: ...27...

Отзывы: