46
•
in our Conrad offices
• at the Conrad collection points
• at the collection points of public waste management authorities or the collection points set up by manufacturers or
distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in countries outside of
Germany.
b) (Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them separately from the product. According to the
Battery Directive, end users are legally obliged to return all spent batteries/rechargeable batteries; they must not be
disposed of in the normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled with this symbol to indicate
that disposal in household waste is forbidden. The abbreviations for heavy metals in batteries are: Cd =
Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the
left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever (re-
chargeable) batteries are sold. You thus fulfil your statutory obligations and contribute to environmental protection.
Batteries/rechargeable batteries that are disposed of should be protected against short circuit and their exposed ter-
minals should be covered completely with insulating tape before disposal. Even empty batteries/rechargeable batter-
ies can contain residual energy that may cause them to swell, burst, catch fire or explode in the event of a short circuit.
16. Technical data
The maximum voltage between the terminal and earth line, or any two terminals is 30 V.
Power supply ....................................................
6x Ni-MH AA-sized battery
Range selection ................................................manually
Operating temperature .....................................
-10 to +55 °C
Storage temperature .........................................
-20 to +70 °C
Relative humidity ..............................................
≤90 % (0 to +30 °C), ≤75 % (+30 to +40 °C), ≤50 % (+40 to +50 °C)
Operating altitude .............................................0 – 2000 m
Dimensions (W x H x D) ...................................104 x 224 x 63 mm
Weight ..............................................................approx. 650 g (Including batteries)
Содержание 2389432