2.Quick Start

 

 

12 

shown, you can still save current reading by pressing the 

  key.) 

Note:   

 

When  the recording data  exceeds the current range,

 

the  data  will be marked as 

"overload". 

 

When the relative operation is turned on, the recorded data will still be the original 

readings without relative operation. 

 

3.

 

Clear the manual record

: Press the Clear  softkey to clear current  manual record. 

(Note: The auto record data will also be cleared, since they share the same data 

table.) 

Auto Record   

1.

 

Configure the parameters

: Press the front panel 

  key, press the Auto softkey. 

Press the Point softkey to specify the total number of readings to record. The range is 

1 to 1000. 
Press the Interval softkey to specify the time interval between readings. The range is 

15 ms to 9999.999 s. 

 

2.

 

Record data

: Press the Start softkey to start auto record. The 

  icon will show up 

on the top of the display.  Press the End  softkey to stop recording, the recorded 

readings will be displayed in the data table. Press 

  keys to turn the page. 

Note

:   

 

The measurement function can be switched during auto record.   

 

In auto range, the relay switch may cause jitter, the data at this time is invalid.

 

It 

Содержание 2203066

Страница 1: ...VC 7055BT Digital Multimeter Quick Guide...

Страница 2: ...erminals HI Sense and LO Sense Measurement Limits 4 Measurement Category 4 2 Quick Start 5 General Inspection 5 Dimensions 5 Foot Stool Adjustment 6 Front Panel Overview 6 Rear Panel Overview 8 User I...

Страница 3: ...e instrument or other property might occur Safety Symbols Symbols on the Product The following symbol may appear on the product Direct current DC Warning risk of electric shock Alternating current AC...

Страница 4: ...s product Refer to the user s manual for the Measurement Limits before connecting to the instrument Do not exceed any of the Measurement Limits defined in the following section Do not operate without...

Страница 5: ...equency period capacitance diode and temperature test measurements Two Measurement Limits are defined for these terminals HI Input to LO Input Measurement Limit The Measurement Limit from HI Input to...

Страница 6: ...ory II Inputs may be connected to AC mains power up to 600 VAC under Category II overvoltage conditions Measurement category definition Measurement CAT I applies to measurements performed on circuits...

Страница 7: ...l You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged please get in touch with our distributor responsi...

Страница 8: ...w 2 3 4 5 12 1 6 7 8 11 9 10 Figure 2 1 Front panel overview Item Name Description 1 LCD Display the user interface 2 Menu selection Keys Activate the corresponding menu 3 Operation Keys Save Collect...

Страница 9: ...asurements 6 Range Direction Keys When the Range softkey is shown on the right menu you can press the key to switch between auto and manual range Press to enable manual range and increase or decrease...

Страница 10: ...ng will be displayed in the Vice Display 12 Dual Exit Press the key to exit dual display mode Rear Panel Overview 1 3 2 5 4 Figure 2 2 Rear panel overview Item Name Description 1 RS232 Connect the PC...

Страница 11: ...ay Power On 1 Connect the instrument to the 90 240 V AC supply using the supplied power cord Warning To avoid electric shock the instrument must be grounded properly 2 Press down the power button at t...

Страница 12: ...trument damage do not discretionarily switch the measurement function when measuring DC Voltage Measurement DC Voltage AC Voltage Measurement AC Voltage DC Current Measurement DC Current AC Current Me...

Страница 13: ...anel key to save current reading to the data table of the internal memory Auto record After setting number of points sample interval press the Start softkey to start recording After recording you can...

Страница 14: ...ord 1 Configure the parameters Press the front panel key press the Auto softkey Press the Point softkey to specify the total number of readings to record The range is 1 to 1000 Press the Interval soft...

Страница 15: ...l exists please contact us for our service 2 The reading does not change when a current signal is input 1 Check whether the test lead is correctly inserted into the current input terminals I terminal...

Страница 16: ...prevent electrical shock disconnect the instrument from AC mains power and disconnect all test leads before cleaning 2 Clean the outside of the instrument using a wet soft cloth not dripping water Do...

Страница 17: ...in personal injury or death Use only the correct fuse type Failure to do so could result in personal injury or instrument damage Voltage Fuse 90 240 V AC 250 V F1AL To perform the line fuse replacemen...

Отзывы: