Model UT90C: OPERATING MANUAL
21
V
Power or 9-12
low voltage power
charge is about 15 minutes.
Note
z
Choose the right way of charge.
z
When the built-in power is deficiency, the
display will shut off. At the first time to start
up the LCD during charge, it is necessary to
use
button to make the Meter display
the exact present charge voltage.
z
When charge has been completed,
disconnect the connection between the
testing leads and the supply power.
General Specifications
z
Maximum Voltage between any Voltage Input
Terminals and COM Terminal: 1000Vp.
z
Fuse protection of µA mA terminal: 500mA
250V fast melt fuse.
z
Fuse protection of 20A terminal: 20A 600V
fast melt fuse.
z
Equipped with full icons display.
z
Maximum Display: Display: 2000.
z
Measurement Speed: Updates 3 times
/second.
z
Range: Auto/Manual.
z
Polarity: Automatically display.
z
Over load indicator: “
OL
”.
z
Battery Deficiency: Display
.
z
Temperature: