Warning
To avoid injury to the user, please do not
attempt the voltage higher than 60V/DC or
30V/AC.
Use the diode test to check diodes, transistors,
and other semiconductor devices. The diode test
sends a current through the semiconductor
junction, then measures the voltage drop across
the junction.
To test a diode out of a circuit, connect the Meter
as follows:
1.
Insert the red test lead (anode “+”) into the
Hz V
Ω
terminal and the black test lead
(cathode “-”) into the
COM
terminal.
2.
Set the rotary switch to
Ω
&
, press
SELECT
button to choose
range. Then
place the red test lead on the component’s
anode and place the black test lead on the
component’s cathode.
3.
For forward voltage drop readings on any
semiconductor component, the measured
value shows on the display.
Note
z
In a circuit, a good silicon junction should
still produce a forward voltage drop reading
of 500mV to 800mV.
z
Connect the test leads to the proper
terminals as mentioned above to avoid
error display. The LCD will display
“OL”