5
CLEANING THE EXHAUST FILTER
30
Open the filter grill.
31
Remove the exhaust filter.
32
Rinse it under tap water and dry it completely.
31
Put the filter back into the cleaner.
30
Close the filter grill.
Exhaust filter reference number: Menalux F110
TROUBLE FINDING YOUR MENALUX FILTERS?
If you do not find Menalux at yours tore , please call Volta
customer service on 1300 365 305 (Aus), 0508 730 730 (NZ).
OPERATING THE HOSE IN/OUT OF THE SUCTION INLET
33
To connect the hose into the suction inlet push it until
it clicks. To disconnect the hose from the suction inlet
push the button at the end of the hose.
WARNING:
On collection of proprietary carpet conditioning
powders, plaster/concrete dust, it is recommended that the
dust container is emptied and the cartridge filter is cleaned
after every use. Some of the preparations contain substances
which while left in the vacuum cleaner for extended periods
could create damage.
Many air fresheners, household deodorants, sprays and
polishes contain highly inflammable gas propellants. Because
of this it is particularly important that these products are
used strictly in accordance with the relevant manufacturers
instructions. It is essential that none of the above products
are sprayed directly into the vacuum cleaner.
TROUBLE SHOOTING AND CUSTOMER INFORMATION
The vacuum cleaner does not start.
1.
Check whether the dust container is full, if so empty
and clean the cartridge filter if showing build up of
dust residue, also inspect the exhaust filter, If severely
discoloured it is to be replaced.
2.
Check that the plug and the cable are not damaged.
3.
Check for a blown fuse.
The vacuum cleaner stops when in use.
1.
Check whether the dust container is full, if so empty
and clean the cartridge filter if showing build up of
dust residue, also inspect the exhaust filter. If severely
discoloured it is to be replaced.
2.
Is the nozzle, tube or hose blocked?
3.
Are the filters blocked?
Blockages and dirty filters can result in the cleaner switching
off in operation, due to restriction of air flow causing the
activation of the thermal overload. If this does occur switch
off the cleaner at the mains and remove the plug. Allow the
cleaner to cool for 20 - 30 minutes. In this time check the hose,
tubes and nozzle for blockages.
(a) To check for a hose blockage pass a small coin through
it, on finding the blockage remove it by pressing the hose to
dislodge and loosen the obstruction. However be careful in
the case it has been caused by glass or needles caught inside
the hose at the point of the blockage.
(b) By passing a flexible tube through the hose from the
handle end the blockage can also be removed.
If the obstruction can not be removed please consult the
Service Providers listing supplied with the cleaner for your
closest Volta Authorised service provider. The clearing of
a blocked hose is not covered by warranty.
Water has entered the vacuum cleaner.
It will be necessary to replace the motor by an authorised
Volta service agent. Damage to the motor caused by the
penetration of water is not covered by the warranty.
CUSTOMER INFORMATION
Should you require service or consumable spares for your
Volta cleaner, please consult the service providers listing
enclosed with this cleaner for your nearest Electrolux
authorised service provider or contact the Customer
service help line on 1300 365 305 (Aus), 0508 730 730 (NZ).
PROTECTING THE ENVIRONMENT
•
Attempt to recycle packaging material and
old appliances.
•
The cardboard packaging can be placed in the
waste paper collection.
•
Deposit the plastic bag made of polyethylene (PE)
at the PE collection point for recycling.
•
Deposit the polystyrene foam at the PS collection
point for recycling.
RECYCLING THE APPLIANCE AT THE END OF ITS LIFE:
•
The plastic components all carry a material
identification marking so that, like the other materials,
they can recycled at the end of the life of the appliance.
•
Please inquire with your local authority.
BLOCKED AIR FLOW AND DIRTY FILTERS
•
The cleaner stops automatically if a blockage occurs
in the nozzle/tube/hose or if the filters are blocked
with dirt.
•
Disconnect from mains and allow the cleaner to
cool for 20-30 minutes. Remove blockage and/or
clean filters.
•
Restart the cleaner.
The symbol
on the product or on its packaging indicates
that this product may not be treated as household waste.
Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment
and human health, which could otherwise be caused by
inappropriate waste handling of this product. For more
detailed information about recycling of this product, please
contact your local city office, your household waste disposal
service or the shop where you purchased the product
MAINTENANCE AND CUSTOMER INFORMATION
35117_U1661 Lite_IFU_V4.indd 5
8/10/08 9:43:31 AM