background image

VOLT

®

 G2 Big Par36 Cast Brass Flood Light

VFL-4501-4-BBZ

INSTALLATION INSTRUCTIONS

w w w . v o l t l i g h t i n g . c o m

- 2 -

Important: Please Read Before Installation

Important Safety Instructions

This luminaire is intended for installation in accordance with local codes 

and the National Electric Code (NEC). Failure to adhere to these codes and 

instructions may result in serious injury, property damage and void the 

warranty.

These instructions do not intend to cover all variations in installation, 

operation maintenance or mounting situation.

1.  Make sure that the power is turned OFF before installing or servicing 

this luminaire.

2.  WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M) 

or more from pool, spa or fountain.

3.  This luminaire is intended to be used only with a power supply 

(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.

4.  Wiring connections must be made with UL Listed wire connectors that 

is suitable for outdoor use.

5.  Position the low voltage wire and UL listed wire connector so that 

it is located within 6 inches (15.2 cm) from a building structure, a 

luminaire or fitting.

6.  The main low voltage cable is intended for shallow burial - less than 6 

inches (152 mm).

7.  If additional lengths of low voltage cable is required, please contact         

www.voltlighting.com or call 1-813-978-3700.

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS

Lighted lamp is HOT!

WARNING – TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS.

1.  Lamp gets HOT quickly! 
2.  Do not touch the hot lens, guard or enclosure.
3.  Keep lamp away from materials that may burn.
4.  Do not touch lamp at any time. Use a soft cloth. Oil from skin may 

damage lamp.

5.  Do not operate the luminaire fitting with a missing or damaged shield.

SAVE THESE INSTRUCTIONS

!

!

Содержание VFL-4501-4-BBZ

Страница 1: ...501 4 BBZ INSTALLATION INSTRUCTIONS Specifications and product details subject to change without notice Copyright 2020 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST 1 ...

Страница 2: ...only with a power supply transformer rated maximum of 300 watts 25 AMPS at 15 volts 4 Wiring connections must be made with UL Listed wire connectors that is suitable for outdoor use 5 Position the low voltage wire and UL listed wire connector so that it is located within 6 inches 15 2 cm from a building structure a luminaire or fitting 6 The main low voltage cable is intended for shallow burial le...

Страница 3: ...ounting Accessory customersupport voltlighting com 813 978 3700 3 Product Dimensions 2 3 4 65 4 25 Remove Glare Guard 1 A 1 Fixture Rotate the glare guard counter clockwise and remove it from the fixture Then remove the bulb holder ROTATE Fixture Bulb Holder Glare Guard ...

Страница 4: ...ect the supply wires using the screws on the bottom of the PAR36 bulb tighten with a screwdriver CAUTION Do not exceed maximum wattage marked on luminaire label NOTE DO NOT touch lamp with bare hands Use soft cloth to handle lamp Install Bulb Holder and Glare Guard Glare Guard Tuck the excess wires inside of the fixture and place the PAR36 bulb inside Place the bulb holder onto the top of the PAR3...

Страница 5: ...e to the stake place a board on top of the stake while hammering Note If the ground is hard and the stake is difficult to install make a crosscut in the ground using a flat shovel Install Fixture to Stake Fixture Wireway Slot Ground Soil Stake Cable Clear away an area in the ground at the wireway slot on the top of the stake Place the fixture wire into the wireway slot and thread the fixture onto ...

Страница 6: ...onnectors Main Supply Cable Strip both leads from the fixture pigtail Using two UL listed wire connectors sold separately connect the leads from the fixture to the main supply cable leads Fixture Supply Wire Adjust Fixture Fixture Screw ROTATE Loosen the knuckle and adjust the fixture to the desired orientation Tighten the knuckle after you find the desired orientation ...

Страница 7: ...R36 Bulb Reverse Step 1 Step 3 to expose the PAR36 bulb and replace it with correct wattage and type marked on luminaire label Reinstall glare guard IMPORTANT Halogen lamps must be protected from moisture and dust at all times Always reinstall glare guard when removed ...

Страница 8: ...details subject to change without notice Copyright 2020 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 w w w v o l t l i g h t i n g c o m Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST 8 ...

Отзывы: