6
Table 1-1 IntelliTec Control Settings
IntelliTec Control Setting Specifi cations
Basic Menu
DISPLAY
Value
MODE
DEFINITION
CutOut
*
Serve
Amp draw setting for cut out
Cut In T
21°F
Serve
Temperature setting for cut in
Cycles
20
Serve
Freezing cycles before going into Standby Mode
Stir On
15 sec
Serve
Stir-only on time
Stir Off
300 sec
Serve
Stir-only off time
Advanced Menu
DISPLAY
Value
MODE
DEFINITION
On Time
28 sec
Standby
Freezing cycle “on” time (runs on timers only)
Off Time
450 sec
Standby
Freezing cycle “off” time
Stb Time
120 sec
Standby
Total time in mode
Sl1DrvOn
120 sec
Sleep 1
Drive motor “on” timer
Sl1DrOff
180 sec
Sleep 1
Drive motor “off” timer
Sl2CutIn
32°F
Sleep 2
Cut in temperature
Sl2CtOut
28°F
Sleep 2
Cut out temperature
DftOffTm
600 sec
No Sensor Default “off” time. Used in case of sensor failure
Storage Menu
DISPLAY
Value
MODE
DEFINITION
Refriger
Cabinet
All
Set to None, 1 Hopper, 2 Hopper, or Cabinet
CabCutIn
37°F
All
Refrigerated cab cut in temperature
CabCtOut
33°F
All
Refrigerated cab cut out temperature
Cab Off
13 min
No Sensor Default “off” time. Used in case of sensor failure
Cab On
130 sec
No Sensor Default “on” time. Used in case of sensor failure
* The CutOut value needs to be adjusted to product requirements. Refer to the 2187295 - Speci
fi
cation Sheet for O431
Control located in the plastic pouch behind the header panel.
Содержание Stoelting O431
Страница 1: ...Model O431 SERVICE MANUAL Manual No 513641 Rev 1...
Страница 2: ......
Страница 8: ......
Страница 28: ...20...
Страница 36: ...28...
Страница 46: ...38...
Страница 54: ...46...
Страница 73: ...65 0 0 0 8 14 REFRIGERATION DIAGRAM AND WIRING DIAGRAM...
Страница 74: ...66...