Operating manual VAS 5051B A01.4 08/04 All rights reserved.
2-8
VAS 5051B
2.3.2
Temperature Sensor
2.3.3
Pressure Sensor
2.3.4
Digital Storage Oscilloscope (DSO)
T/P measuring input
The measuring input is designed for connection of a
temperature sensor with a PT100 measuring element.
T/P measuring input
The measuring input is designed for connection of a
pressure sensor with a 4 mA to 20 mA interface.
Caution
Maximum voltage on DSO measuring lead: 400 V
peak
or 400 V DC
Measuring leads
DSO1/DSO2 measuring leads
kV pick-up
Trigger pick-up
Current pick-up 100 A, 1800 A
Pressure or temperature sensor
Measurement inputs
DSO1, DSO2
Make sure that both measurement connections are
adapted on each cable.
Bandwidth
100 kHz (±3 dB)
Resolution 10
Bit
Accuracy DC to 10 kHz ±1 %; 100 kHz -3 dB
Measurement range selec-
tion
Manual or automatic in Auto Setup