Volkswagen Touareg 2 2007 Скачать руководство пользователя страница 2

 

 

Technical Bulletin 

 

 

Page 2 of 5 

 

© 2008 Volkswagen Group of America, Inc. 

All rights reserved.  Information contained in this document is based on the latest information available at the time of printing and is subject to the copyright and other intellectual 

property rights of Volkswagen Group of America, Inc., its affiliated companies and its licensors. All rights are reserved to make changes at any time without notice.  No part of this 

document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, nor may these 

materials be modified or reposted to other sites, without the prior expressed written permission of the publisher.

  

Vehicle requirements: 

 

 

 Note:

 

 

Non-observance of the following points may lead to module failure! VAS 5051 or VAS 5052 must always be 
connected to an approved power supply at the approved voltages. Under no circumstances should the power 
supply be interrupted or the diagnostic connector unplugged during the update programming procedure. Any 
appliances with high electromagnetic radiation must be turned off. (i.e. mobile phones)

 

Volkswagen Brand CD from V.12.83.00 as well as the Basic CD version 12.00 or higher must be installed. 

Battery MUST have a minimum no-load charge of 12.5 volts. (Failure to maintain voltage during update process 
may result in control module failure.  

Use INC-940 battery charger to maintain voltage during the procedure.  

Workshops which have a networked VAS diagnostic tester can run an online update of control unit using SVM 
(software version management).  

 

 

 Tip:

 

SVM process must be completed in it’s entirety so the database receives an update confirmation response. A 
warranty may not be reimbursed if there is no confirmation response to support claim. For further update 
instructions and troubleshooting, refer to SVM Technical Bulletin 2014603 in Elsa Web.

 

 

Procedure for updating is in the Guided Fault Finding/ Function Component Selection/Software Version 
Management, Adapt Software.  

 

The SVM unit code is supplied in chart below.  

 
 

Old Control Module 

Part No.

 

Old Software Version

 

New Control 

Module Part No.

 

New  Software 

Version

 

SVM Unit Code

 

7L6 959 107 

X104, X110, X120 X300, 

X310, X320, X401, X501, 

X601, X602, 0701, 1108, 

1110 

7L6 959 107 B 

1310 

30D6 

7L6 959 107 A 

1210 

7L6 959 107 B 

1310 

30D6 

 

 

Отзывы: