-> There are always 4 display zones in the measured value block (if necessary in physical quantities).
Decoding the individual values in display zones 1 to 4 =>Test table page
List of selectable display group numbers
Indicated on display (example)
Display zones:
1 2 3 4
ï ï ï ï
Display group No. Display zone
Description
Read measured value block 1⇒
P 0.8 V 0 % 00000111
001
1
2
3
4
Selector lever position
Throttle valve potentiometer voltage
Accelerator pedal value
Switch positions
Read measured value block 2⇒
0.983 A 0.985 A 12.76 V 2.50 V
002
1
2
3
4
Solenoid valve 6 -N93- actual current
Solenoid valve 6 -N93- specified current
Battery voltage
Voltage at road speed sender -G68-
Read measured value block 3⇒
0 km/h 900 rpm 0 0 %
003
1
2
3
4
Speed
Engine speed
Gear selected
Accelerator pedal value
Read measured value block 4⇒
1000 00 0 P 0 km/h
004
1
2
3
4
Solenoid valves
Gear selected
Selector lever position
Speed
Read measured value block 5⇒
40°C 0011011 0 900 rpm
005
1
2
3
4
ATF temperature
Selector output
Gear to be selected
Engine speed
Display zones:
1 2 3 4
ï ï ï ï
Display group No. Display zone
Description
Read measured value block 6⇒
006
1
2
3
4
Can be disregarded
Read measured value block 7⇒
1H+/-200 rpm 900 rpm 0 %
007
1
2
3
4
Gear selected (+ or - sign relates to display
zone 2)
Lock-up clutch slip
Engine speed
Accelerator pedal value
Read measured value block 8⇒
008
1
2
3
4
Can be disregarded
◆ If the printer is switched on, the current display is printed out on the log.
◆ If the specified values are obtained in all the display zones:
- Press key ⇒.
-> Indicated on display:
Rapid data transfer HELP
Select function XX
Golf 1998 ➤
Automatic gearbox 01M self-diagnosis - Edition 10.1997
3.8 - Read measured value block