Modular IoT Gateway User Guide
V1R1
www.volansys.com
I Email:
Copyright
©
2017 VOLANSYS
Page |
11
Switch configuration for different boot mode selection is shown in below table:
BMODE
[1:0]
BOOT Mode
0 0
Boot from fuses
0 1
Serial Downloader
1 0
Internal Boot
1 1
Reserved
Table 3 - i.MX6 Ultra Lite SOM DIP SW01 Configuration
Figure 6 - SW01 Settings for Boot Mode Selection
Note: Please see Annex-I for SW01 Boot mode setting for production batch serial number:
17030171XXXXX to 17030295XXXXX and MAC: 70-B3-D5-9A-E07A to 70-B3-D5-9A-E0F6
3.2.1
Serial Downloader
Modular Gateway supports serial download option for initial boot process.
It is also required to change USB mode to device for serial download. USB-2 (J17) connector supports
both modes. Details for USB mode change is provided in sec. 3.5.