35
IMPORTANT
A GAS SOUNDNESS CHECK MUST BE
CARRIED OUT IF ANY GAS CARRYING
COMPONENTS HAVE BEEN REMOVED,
REPLACED, OR DISTURBED .
FAN SPEED (rpm) TABLE - LPG
MODEL
MAX
MIN
HTG
IGN
28HE
6100
1700
4300
3700
32HE
5900
1500
4500
3700
36HE
6300
1400
5200
3700
10.7
APPLIANCE FAN SPEEDS
The appliance fan speeds require to be checked
and/or adjusted prior to making any adjustments
to the gas valve or if the main PCB has been
replaced.
ATTENTION
Gas type and appliance fan speed (output)
must
be set
according to the specific appliance
specification. Vokera accepts no responsibility if
the gas type and/or fan speed is not correctly
adjusted according to the respective appliance
specification as detailed on the appliance data
badge.
10.7.1 CHECKING/ADJUSTING THE APPLIANCE FAN
SPEEDS
Move the selector switch to the OFF position and
remove the 3-selector knobs.
10.7.2 ABSOLUTE MAX FAN SPEED
Locate the MAX trimmer (fig. 36) and gently adjust
clockwise or counter clockwise to achieve the
correct fan speed (see table above). NOTE, the
display shows the fan RPM in multiples of 1000,
i.e. 2.5 = 2500RPM.
10.7.3 ABSOLUTE MIN FAN SPEED
Locate the MIN trimmer (fig. 36) and gently adjust
clockwise or counter clockwise to achieve the
correct fan speed (see table above). NOTE, the
display shows the fan RPM in multiples of 1000,
i.e. 2.5 = 2500RPM.
10.7.4 IGNITION FAN SPEED
Locate the IGN trimmer (fig. 36) and gently adjust
clockwise or counter clockwise to achieve the
correct fan speed (see table above). NOTE, the
display shows the fan RPM in multiples of 1000,
i.e. 2.5 = 2500RPM.
10.7.5 HEATING FAN SPEED
Locate the HTG trimmer (fig. 36) and gently adjust
clockwise or counter clockwise to achieve the
correct fan speed (see table above). NOTE, the
display shows the fan RPM in multiples of 1000,
i.e. 2.5 = 2500RPM.