Supplied By www.heating spares.co Tel. 0161 620 6677
16
Do not remove the link wire (between TA & Spare)
unless additional external controls are to be fitted
(see section 8).
4.7.4
CONNECTING THE VOKERA TIME CLOCK
(part no. 201 & 202)
The appliance is supplied with a clock connector
plug that is connected to plug M16 on the
appliance terminal block. The clock connector
plug is for use with the clock harness that is
included in the accessory pack and facilitates an
easy connection to the optional Vokera time clock.
To fit the Vokera time clock:
●
remove the appliance PCB cover
●
remove and discard the wiring harness
supplied with the clock
●
using the clock wiring harness supplied in the
accessory pack, connect the 4-wires to the
clock as shown in fig 16.
Fig. 16
Fig. 17
●
remove the clock aperture plate from the
appliance
●
remove the push-out blanking disc from the
clock aperture plate (fig. 17)
●
secure the clock to the aperture plate using
the screws provided with the clock (fig. 17)
●
refit the clock aperture plate ensuring the clock
is positioned the correct way up
●
remove the Red link-wire plug from the
appliance clock connector plug
●
connect the clock wiring harness to the clock
connector plug
●
re-fit the appliance PCB cover and terminal
cover.
The securing screw on the cable anchorage
should now be tightened. This must be done
before the control fascia is re-fitted in the upright
position. The appliance casing and screws can