Supplied By www.heating spares.co Tel. 0161 620 6677
31
7.10.3 FAULT FINDING TEST ‘A1’
NO
YES
A1
REPLACE
CONTROL BOARD
FUSE OK
CHECK FUSE F1
ON CONTROL
BOARD
RED LED
BLINKS
MAINS
PRESENT BETWEEN
TERMINALS CN1.2
&CN1.3 M2.2 ON
CONTROL
YES
NO
RESTART THE
TEST
REPLACE FUSE
NO
NO
REPLACE CONTROL
BOARD
RED LED
LIGHT
YES
YES
SWITCH ON/OFF
SELECTOR ON OFF
POSITION
SWITCH ON/OFF
SELECTOR TO
WINTER POSITION
GREEN LED
BLINKS
RESTART THE
TEST
YES
YES
NO
CHECK CH NTC
SENSOR OR WIRING
AND CONNECTIONS
YELLOW
LED
LIGHT
NO
CHECK WIRING AND
CONNECTIONS, WATER
PRESSURE SWITCH AND
HYDRAULIC CIRCUIT
NO
RECHECK SUPPLY
FUSE &
CONNECTORS TO
BOILER
TERMINALS
MAINS
PRESENT BETWEEN
BLUE & BROWN WIRES AT
BOILER TERMINAL
STRIP
NO
REPLACE WIRING OR
CONNECTIONS
TERMINAL STRIP AND
CONTROL BOARD
YES
YELLOW LED
BLINKS
CHIMNEY
SWEEPER CYCLE.
RESET AND
RESTART TEST
NO
IS
THERE 0 VCC
BETWEEN TERMINALS
CN9.1 & CN9.2
ON PCB
IS
THERE 24 Vdc
BETWEEN TERMINALS
CN8.4 & CN8.7
ON PCB
IS
THERE 24 Vdc
BETWEEN TERMINALS
CN8.4 & CN8.8
ON PCB
REPLACE
CONTROL BOARD
CHECK WIRING AND
CONNECTIONS OR
HIGH LIMIT THERMOSTAT
IS
THERE 24 Vdc
BETWEEN TERMINALS
CN8.4 & CN8.6
ON PCB
REPLACE
CONTROL BOARD
IS
THERE 24 Vdc
BETWEEN TERMINALS
CN8.4 & CN8.5
ON PCB
CHECK WIRING AND
CONNECTIONS OR
AIR PRESSURE SWITCH
REPLACE
CONTROL BOARD
YES
YES
YES
YES
YES
NO
NO
NO
NO
YES
BOARD