21
SECTION 8
WIRING DIAGRAMS
8.1
EXTERNAL WIRING
The appliance comes with a factory fitted cable
that should be connected to a suitable fused
isolator or plug. If this is unsuitable and a direct
connection to the appliance is required, it must be
connected to the appliance as shown in the
following diagram. For further advice on the
electrical connection, please contact Vokera
technical on 0870 333 0520.
TR1
DHW temperature control
TR2
Selector ON/OFF
JP1
Natural gas or LPG selector jumper
P.F.
Air pressure switch
T.L.
High limit thermostat
SAN
Flow switch
F1
Fuse 2A F
E.A.R.
Sense/ignition electrode
RL1
Fan relay
NOTE: L-N connection is advisable
RL2
Ignition relay
MOD
Modulator
V
Fan
IWH01X
Control board
T1
Transformer
OPE
Gas valve solenoids
CN1-CN7 Connectors
T2
Ignition/transformer
FUNCTIONAL DIAGRAM