V-6016
•
Pass-through fax and T.38 fax.
4.3 -
List of components in the package
•
One V-6016 SIP adapter.
•
One power supply.
•
One Ethernet UTP5 cable with RJ-45 connectors.
•
One RJ-11 telephone cable.
•
User manual.
4.4 -
Getting started
Before connecting the V-6016 adapter to the network, please make sure that both your
network and VOIspeed server are working correctly.
NB: before you can use any analogue devices connected to the V-6016 adapter you will
need to create additional users at the server PBX.
4.5 -
Installation
Connections
•
Connect the device’s LAN Ethernet port to a switch/router/hub using an UTP5
Ethernet cable (not cross cable).
•
Connect any devices or additional V-6016 adapters to the PC Ethernet port using an
UTP5 Ethernet cable (not cross cable).
•
Connect any analogue devices (telephone/fax) to the FXS1 and FXS2 ports.
•
Connect the power supply to the Power plug
This device is provided with a ground connection. Use the device only in a fully earthed
electric system, with Residual Current Device (RCD) and relevant safety measures as
prescribed by law. Please also make sure that the voltage complies with that required by
the device. Contact technical support if in any doubts.
4.6 -
LEDs
There are four LEDs mounted on the V-6016. They display the status of the resources
connected to the device. The table below reports the colours associated to each resource
status:
Green
Off
Flashing green
LAN
Local network UP
Local network DOWN
Data flow
PC
Connection UP
Connection DOWN
Data flow
FXS1
Registered user
Inactive line
Active call
FXS2
Registered user
Unregistered user
Active call