4 Cable and Wiring
4.1 Electrical safety
To avoid electrical hazards please note the following:
• Do not access the inside of any electrical equipment. Refer servicing to
Void-approved service agents
4.2 Cable considerations for fixed installations
We recommend specifying installation-grade Low Smoke Zero Halogen (LSZH) cables for
permanent installations. Cables for permanent installations should be compliant with the
following standards:
• IEC 60332.1 Fire retardancy of a single cable
• IEC 60332.3C Fire retardancy of bunched cables
• IEC 60754.1 Amount of Halogen Gas Emissions
• IEC 60754.2 Degree of acidity of released gases
• IEC 61034.2 Measurement of smoke density
Tri Motion loudspeakers are 3-way, bi-amplified. They require two amplifier channels to drive
them via 4-core speakON
TM
NL4 cables. We suggest using the following maximum copper
cable lengths to keep level losses below 0.6 dB.
Metric mm
2
Imperial AWG
8
Ω
load
4
Ω
load
2
Ω
load
2.50 mm
2
13 AWG
36 m
18 m
9 m
4.00 mm
2
11 AWG
60 m
30 m
15 m